MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12874-025-02628-9

Медицинская библиотека · BMC medical research methodology · 2025

Power and sample size considerations for test-negative design with bias correction: a case study on the world first malaria vaccine.

Ko Yura K, Alfvén Tobias, Yoneoka Daisuke

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Test-negative design (TND) studies are increasingly common in evaluating vaccine effectiveness (VE) for various infectious diseases. TND studies are susceptible to bias due to disease outcome misclassification caused by imperfect test sensitivity and specificity. Several bias correction methods have been proposed. However, sample size or power considerations for TND studies incorporating bias correction for such misclassification have not yet been investigated.

METHODS

We used Monte Carlo simulations to assess how bias correction affects the statistical power and sample size for VE estimation in TND studies. Simulations were conducted under varying levels of diagnostic test sensitivities (60%, 80%, and 95%). Bias correction was implemented using the multiple over-imputation method, which accounts for test misclassification through a parametric bootstrapping approach. Using a malaria vaccine as an example, we defined six vaccination status categories based on the time since receipt of the third or fourth vaccine dose. In the simulated target population, vaccination coverage was assumed to be low (< 10%) except for the group vaccinated more than 12 months after dose 4. We assumed relatively low VE (< 50%) against clinical malaria cases and a 30% malaria positivity rate among unvaccinated individuals presenting with malaria-related symptoms. Statistical power to detect VE was estimated for each vaccination status, both with and without bias correction.

RESULTS

Estimated VEs based on observed data were consistently underestimated across all vaccination status groups due to diagnostic misclassification. In contrast, bias-corrected estimates were approximately unbiased but displayed wider confidence intervals, with their precision decreasing at lower test sensitivities. Statistical power to detect VE declined substantially when diagnostic test sensitivity was low. For instance, at 80% sensitivity, only three vaccination status groups reached 80% power with a sample size of 10,000, whereas the same power was achieved with just 6,000 individuals under a perfect test.

CONCLUSIONS

Bias due to imperfect diagnostic testing can substantially reduce the power of TND studies. Power calculations should account for outcome misclassification and potential correction methods. Failure to do so may lead to underpowered studies and misleading VE estimates.

Для цитирования: Ko Yura K, Alfvén Tobias, Yoneoka Daisuke. Power and sample size considerations for test-negative design with bias correction: a case study on the world first malaria vaccine.. BMC medical research methodology. 2025. DOI: 10.1186/s12874-025-02628-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.