m+Medelevator.RU
← Поиск публикаций
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2023

Autograft reoperations after the Ross procedure.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Abeln Karen B, Ehrlich Tristan, Souko Idriss, Brenner Friederike, Schäfers Hans-Joachim

Аннотация

OBJECTIVES: After a Ross procedure, autograft failure can occur. At reoperation, repair of the autograft preserves the advantages of the Ross procedure. The aim of this retrospective study was to assess mid-term results after reoperation of a failed autograft.

METHODS: Between 1997 and 2022, 30 consecutive patients (83% male; age 41 ± 11 years) underwent autograft reintervention between 60 days and 24 years (median 10 years) after a Ross procedure. The initial technique varied, full-root replacement (n = 25) being the most frequent. The indication for reoperation was isolated autograft regurgitation (n = 7), root dilatation (>43 mm) with (n = 17) or without (n = 2) autograft regurgitation, mixed dysfunction (n = 2) and endocarditis (n = 2). In 4 instances, the valve was replaced by valve (n = 1) or combined valve and root replacement (n = 3). Valve-sparing procedures consisted of isolated valve repair (n = 7) or root replacement (n = 19), and tubular aortic replacement. Cusp repair was performed in all but 2. Mean follow-up was 5.4 ± 6 years (35 days to 24 years).

RESULTS: Mean cross-clamp and perfusion times were 74 ± 26 and 132 ± 64 min. There were 2 perioperative deaths (7%; both valve replacement) and 2 patients died late (32 days to 1.2 years postoperatively). Freedom from cardiac death at 10 years was 96% after valve repair and 50% after replacement. Two patients required reoperation (1.68 and 16 years) following repair. One underwent valve replacement for cusp perforation, the other, root remodelling for dilatation. Freedom from autograft reintervention at 15 years was 95%.

CONCLUSIONS: Autograft reoperations after the Ross procedure can be performed as valve-sparing operations in the majority of cases. With valve-sparing, long-term survival and freedom from reoperation are excellent.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты