m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2022

Minimalist transcatheter aortic valve replacement misses paravalvular regurgitation: Incidence and echocardiographic distribution of missed paravalvular regurgitation.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zaid Syed, Haniyeh Ahmed Abu, Rosenzveig Akiva, Malik Aaqib, Goldberg Joshua B, Undemir Cenap, Spevack Daniel, Lansman Steven L, Tang Gilbert H L, Ahmad Hasan

Аннотация

BACKGROUND: Paravalvular regurgitation (PVR) may be missed intraoperatively with transthoracic echocardiography (TTE) guided minimalist TAVR. We sought to determine the incidence and echocardiographic distribution of PVR missed on intra-op TTE, but detected on predischarge TTE.

METHODS: From July 2015 to 2020, 475 patients with symptomatic severe native aortic stenosis underwent TTE-guided minimalist TAVR. Missed PVR was defined as predischarge PVR that was ≥1 grade higher than the corresponding intra-op PVR severity. PVR was classified as anterior or posterior on the four standard TTE views; parasternal short-axis (PSAX), parasternal long-axis (PLAX), apical 3-chamber (A3C), and 5-chamber (A5C). Location-specific risk of missed PVR was then determined.

RESULTS: Mild or greater PVR was seen in 55 (11.5%) cases intra-op and 91 (19.1%) at predischarge, with no severe PVR. Among the 91 patients with ≥mild predischarge PVR, missed PVR was present in 42 (46.2%). Compared to the corresponding anterior jets, missed PVR rate was significantly higher for posterior jets in PLAX (62.5% vs. 25.0%, p = 0.005), A5C (56.9% vs. 25.0%, p = 0.009), PSAX (66.7% vs. 24.3%, 0.001), but not A3C (58.5% vs. 40.0%, p = 0.28).

CONCLUSIONS: Intraoperative TTE-guided minimalist TAVR either misses nearly half of ≥mild PVR or underestimates PVR by ≥1 grade when compared to predischarge TTE. Posterior PVR jets are more likely to be missed. Transesophageal echo guidance may help minimize missing PVR. Further studies are warranted.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты