Minimalist transcatheter aortic valve replacement misses paravalvular regurgitation: Incidence and echocardiographic distribution of missed paravalvular regurgitation.
Аннотация
BACKGROUND
Paravalvular regurgitation (PVR) may be missed intraoperatively with transthoracic echocardiography (TTE) guided minimalist TAVR. We sought to determine the incidence and echocardiographic distribution of PVR missed on intra-op TTE, but detected on predischarge TTE.
METHODS
From July 2015 to 2020, 475 patients with symptomatic severe native aortic stenosis underwent TTE-guided minimalist TAVR. Missed PVR was defined as predischarge PVR that was ≥1 grade higher than the corresponding intra-op PVR severity. PVR was classified as anterior or posterior on the four standard TTE views; parasternal short-axis (PSAX), parasternal long-axis (PLAX), apical 3-chamber (A3C), and 5-chamber (A5C). Location-specific risk of missed PVR was then determined.
RESULTS
Mild or greater PVR was seen in 55 (11.5%) cases intra-op and 91 (19.1%) at predischarge, with no severe PVR. Among the 91 patients with ≥mild predischarge PVR, missed PVR was present in 42 (46.2%). Compared to the corresponding anterior jets, missed PVR rate was significantly higher for posterior jets in PLAX (62.5% vs. 25.0%, p = 0.005), A5C (56.9% vs. 25.0%, p = 0.009), PSAX (66.7% vs. 24.3%, 0.001), but not A3C (58.5% vs. 40.0%, p = 0.28).
CONCLUSIONS
Intraoperative TTE-guided minimalist TAVR either misses nearly half of ≥mild PVR or underestimates PVR by ≥1 grade when compared to predischarge TTE. Posterior PVR jets are more likely to be missed. Transesophageal echo guidance may help minimize missing PVR. Further studies are warranted.