m+Medelevator.RU
← Поиск публикаций
Annals of the Royal College of Surgeons of England · 2023

Role of four-dimensional computer tomography (4D-CT) in non-localising and discordant first-line imaging in primary hyperparathyroidism.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sayed S, Das A, Turner B, Wadhwa V S, Pathak K A

Аннотация

BACKGROUND: Accurate preoperative localisation of parathyroid adenoma is imperative for the success of minimally invasive parathyroidectomy (MIP).

OBJECTIVE: Our study aimed to evaluate the role of four-dimensional computer tomography (4D-CT) scan as an imaging modality in patients with failed and discordant localisation reported in the first-line imaging modalities (ultrasonography and 99mTc-MIBI-SPECT/CT).

METHODS: This is a prospective cohort study performed at a university teaching centre from March 2013 to July 2021. All patients with primary hyperparathyroidism who had failed localisation by ultrasonography and 99mTc-MIBI-SPECT/CT (SpCT), or discordance between them, had 4D-CT performed in this study.

RESULTS: One hundred and two sporadic cases of pHPT with failed/discordant first-line imaging had 4D-CT imaging prior to parathyroidectomy. In 102 patients, 105 parathyroid adenomas were reported on histopathology. 4D-CT was able to localise 78% of them to the correct side and 64% to the correct quadrant in 102 patients, as compared with US (correct side 21%, correct quadrant 16%) and 99mTc-MIBI-SPECT/CT (correct side 36%, correct quadrant 31%). 4D-CT had a sensitivity, precision, accuracy and F1 score for correct quadrant localisation as 79%, 81%, 66% and 80%; and for correct side localisation as 82%, 98%, 80% and 89%, respectively. 4D-CT was able to identify three ectopic adenomas (two in superior mediastinum and one in the oesophageal wall) which were not detected on US or SpCT.

CONCLUSION: 4D-CT was found to be sensitive and accurate in preoperative localising of the diseased parathyroid glands after failed/discordant US and SpCT. This led to more patients being offered MIP as the primary surgery and improved operative outcomes.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты