m+Medelevator.RU
← Поиск публикаций
Acta tropica · 2021

Evaluation of a real-time recombinase polymerase amplification assay for rapid detection of Schistosoma haematobium infection in resource-limited setting.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Frimpong Michael, Kyei-Tuffuor Louis, Fondjo Linda Ahenkorah, Ahor Hubert Senanu, Adjei-Kusi Priscilla, Maiga-Ascofare Oumou, Phillips Richard Odame

Аннотация

Accurate diagnosis of urogenital schistosomiasis is vital for surveillance/control programs as well as achieving the WHO 2012-2020 road map for the total eradication of schistosomiasis. Recombinase polymerase amplification (RPA) has emerged as a rapid and simple molecular tool adaptable for fewer resources with diagnostic accuracy similar to polymerase chain reaction (PCR). This rapid molecular assay employs the use of enzymes for the amplification of nucleic acid taget at a constant temperature. The aim of this study was to validate a real-time RPA assay targeting the Dra 1 repittitive sequence of Schistosoma (S.) haematobium and evaluate its use in urogenital schistosomiasis diagnosis. S. haematobium Dra 1 molecular DNA standard was applied to determine the assay's analytical sensitivity. DNA extracts of S. haematobium, other Schistosoma species, protozoa and bacteria species were used to determine the specificity of the RPA assay. Clinical performance of the assay was validated with a panel of 135 urine samples from volunteers of schistosomiasis endemic communities. The developed assay was evaluated with urine samples extracted by just boiling and with SpeedXtract® DNA extraction kit. A specific fragment of S. haematobium Dra 1 repetitive sequence was amplified within 15 minutes at a constant 42˚C using the developed S. haematobium RPA assay. The detection limit was 15 copies of Dra1 molecular DNA standard per reaction. There was no cross-reaction with other protozoan and bacterial species except Schistosoma species, S. mansoni and S. japonicum. Using 135 urine samples, Schistosoma RPA assay had a clinical sensitivity and specificity of 98.4% (95% CI, 91.6-100) and 100% (95% CI, 94.9-99) respectively when compared to S. haematobium Dra 1 qPCR assay. The diagnostic performance of S. haematobium real-time RPA assay was not affected by the use of crude DNA extracted samples. The S. haematobium RPA assay can serve as an alternative to PCR, especially in low resource settings.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты