Findeisen Hajo, Görg Christian, Winter Helen, Trenker Corinna, Dietrich Christoph F, Alhyari Amjad, Eilsberger Friederike, Safai Zadeh Ehsan
Аннотация
PURPOSE: To assess splenic involvement using B-mode ultrasound (US) and contrast-enhanced ultrasound (CEUS) compared with standard imaging with contrast-enhanced computerized tomography (CT) / 18-fluorodeoxyglucose positron-emission tomography (PET-CT) in patients with Hodgkin lymphoma.
MATERIALS AND METHODS: Imaging data from 112 patients from 12/2003 to 10/2022 with histologically confirmed Hodgkin lymphoma during staging or relapse were analyzed for splenic lymphoma involvement. In all patients, standard imaging (CT/PET-CT), along with B-mode US and CEUS examinations, was performed. Evidence of focal splenic lesions (FSLs) found by imaging procedures was suggestive of splenic involvement. Follow-up imaging was performed in each patient after treatment, and treatment response indicated definitive splenic involvement.
RESULTS: 40 patients (35.7%) were identified by imaging modalities as having splenic involvement, which was confirmed by response during follow-up. Standard CT/PET-CT imaging detected splenic involvement in 36/112 patients (32.1%). FSLs were detected with B-mode US in 38 patients (33.9%) and CEUS in 36 patients (32.1%). The sensitivity of standard imaging, B-mode US, and CEUS was 90%, 95%, and 90%, respectively.
CONCLUSION: B-mode US examination is a diagnostic method used in addition to standard imaging for the detection of splenic involvement in Hodgkin lymphoma. CEUS does not provide additional benefit compared to B-mode US and the standard reference procedure.
MATERIALS AND METHODS: Imaging data from 112 patients from 12/2003 to 10/2022 with histologically confirmed Hodgkin lymphoma during staging or relapse were analyzed for splenic lymphoma involvement. In all patients, standard imaging (CT/PET-CT), along with B-mode US and CEUS examinations, was performed. Evidence of focal splenic lesions (FSLs) found by imaging procedures was suggestive of splenic involvement. Follow-up imaging was performed in each patient after treatment, and treatment response indicated definitive splenic involvement.
RESULTS: 40 patients (35.7%) were identified by imaging modalities as having splenic involvement, which was confirmed by response during follow-up. Standard CT/PET-CT imaging detected splenic involvement in 36/112 patients (32.1%). FSLs were detected with B-mode US in 38 patients (33.9%) and CEUS in 36 patients (32.1%). The sensitivity of standard imaging, B-mode US, and CEUS was 90%, 95%, and 90%, respectively.
CONCLUSION: B-mode US examination is a diagnostic method used in addition to standard imaging for the detection of splenic involvement in Hodgkin lymphoma. CEUS does not provide additional benefit compared to B-mode US and the standard reference procedure.
Предметные рубрики MeSH
HumansHodgkin DiseaseFemaleMaleAdultSplenic NeoplasmsMiddle AgedContrast MediaRetrospective StudiesUltrasonographyAgedYoung AdultSensitivity and SpecificityAdolescentPositron Emission Tomography Computed TomographyFluorodeoxyglucose F18SpleenImage EnhancementTomography, X-Ray ComputedNeoplasm Staging