European journal of endocrinology · 2023
Bilateral inferior petrosal sinus sampling with human CRH stimulation in ACTH-dependent Cushing's syndrome: results from a retrospective multicenter study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Detomas Mario, Ritzel Katrin, Nasi-Kordhishti Isabella, Schernthaner-Reiter Marie Helene, Losa Marco, Tröger Viola, Altieri Barbara, Kroiss Matthias, Kickuth Ralph, Fassnacht Martin, Micko Alexander, Honegger Jürgen, Reincke Martin, Deutschbein Timo
Аннотация
OBJECTIVE: Bilateral inferior petrosal sinus sampling (BIPSS) is regarded as gold standard to differentiate between Cushing´s disease (CD) and ectopic Cushing's syndrome (ECS). However, published data e.g. on the diagnostic value of additional prolactin analysis is controversial. Thus, we evaluated the diagnostic performance of BIPSS with and without prolactin in a multicenter study.
DESIGN AND METHODS: Retrospective study in 5 European reference centers. Patients with overt adrenocorticotropin (ACTH)-dependent Cushing's syndrome at the time of BIPSS with human corticotropin-releasing hormone stimulation were eligible. Cut-offs for the inferior petrosal sinus (IPS) to peripheral (P) ACTH ratio and the normalized ACTH:prolactin IPS:P ratio were calculated via receiver operator characteristics analyses (reference: CD).
RESULTS: 156 patients with BIPSS were identified. Of these, 120 patients (92 (77%) females; 106 (88%) CD, 14 (12%) ECS) had either histopathologically confirmed tumors or biochemical remission and/or adrenal insufficiency after surgery; only this subgroup was analyzed by ROC analysis. The optimal cut-offs for the ACTH IPS:P ratio were ≥1.9 at baseline (sensitivity 82.1% (95%CI 73.2-88.6), specificity 85.7% (95%CI 56.2-97.5), AUC 0.86) and ≥2.1 at 5 minutes post-CRH (sensitivity 91.3% (95%CI 83.6-95.7), specificity 92.9%(95%CI 64.1-99.6), AUC 0.96). A subgroup underwent additional prolactin analysis. An optimal cut-off of ≥1.4 was calculated for the normalized ACTH:prolactin IPS:P ratio (sensitivity 96.0% (95%CI 77.7-99.9), specificity 100% (95%CI 56.1-100), AUC 0.99).
CONCLUSION: Our study confirms the high accuracy of BIPSS in the differential diagnosis of ACTH-dependent Cushing's syndrome and suggests that the simultaneous measurement of prolactin might further improve the diagnostic performance of this test.
DESIGN AND METHODS: Retrospective study in 5 European reference centers. Patients with overt adrenocorticotropin (ACTH)-dependent Cushing's syndrome at the time of BIPSS with human corticotropin-releasing hormone stimulation were eligible. Cut-offs for the inferior petrosal sinus (IPS) to peripheral (P) ACTH ratio and the normalized ACTH:prolactin IPS:P ratio were calculated via receiver operator characteristics analyses (reference: CD).
RESULTS: 156 patients with BIPSS were identified. Of these, 120 patients (92 (77%) females; 106 (88%) CD, 14 (12%) ECS) had either histopathologically confirmed tumors or biochemical remission and/or adrenal insufficiency after surgery; only this subgroup was analyzed by ROC analysis. The optimal cut-offs for the ACTH IPS:P ratio were ≥1.9 at baseline (sensitivity 82.1% (95%CI 73.2-88.6), specificity 85.7% (95%CI 56.2-97.5), AUC 0.86) and ≥2.1 at 5 minutes post-CRH (sensitivity 91.3% (95%CI 83.6-95.7), specificity 92.9%(95%CI 64.1-99.6), AUC 0.96). A subgroup underwent additional prolactin analysis. An optimal cut-off of ≥1.4 was calculated for the normalized ACTH:prolactin IPS:P ratio (sensitivity 96.0% (95%CI 77.7-99.9), specificity 100% (95%CI 56.1-100), AUC 0.99).
CONCLUSION: Our study confirms the high accuracy of BIPSS in the differential diagnosis of ACTH-dependent Cushing's syndrome and suggests that the simultaneous measurement of prolactin might further improve the diagnostic performance of this test.