Investigation of diaphragmatic motion and projected lung area in diaphragm paralysis patients using dynamic chest radiography.
Аннотация
BACKGROUND
Dynamic chest radiography (DCR) is a novel and supplementary examination in respiratory diseases. The investigation of other chest diseases using DCR has been explored, identifying a certain correlation of the pulmonary function test (PFT). However, there is a lack of research using DCR parameters to quantitatively evaluate chest disease. The purpose of this study was to investigate the diagnostic value of DCR for diaphragm paralysis (DP).
METHODS
This retrospective study recruited 118 participants, which include 18 patients with DP, 48 healthy volunteers, and 52 patients with respiratory disease. Comparison of DCR parameters relationships among 3 groups was performed using one-way analysis of variance (ANOVA) and Kruskal-Wallis test. The receiver operating characteristic (ROC) curve was used to compare the value of the DCR parameters to diagnose DP.
RESULTS
The differences of excursion of diaphragm (ED) in normal (nb) and forced breathing (fb), ED(fb)-ED(nb), and the parameters of projected lung area (PLA) in inspiratory (ins) and expiratory phase (exp), PLA.exp(fb), PLA.ins(fb)-PLA.ins(nb), and PLA.exp(fb)-PLA.exp(nb) among the 3 groups were statistically significant. The highest area under the curve (AUC) of right-side parameter was the ED(fb)-ED(nb), for which the AUC was 0.8950 [95% confidence interval (CI): 0.7618-1.000], whereas that of the left-side parameter was ED(fb), for which the AUC was 0.9176 [95% confidence interval (CI): 0.8524-0.9829].
CONCLUSIONS
The parameters of DCR have good diagnostic value for DP. The highest diagnostic efficiency for DP on the right side is the ED(fb)-ED(nb), with a sensitivity of 95% and a specificity of 78.6%, whereas on the left side is ED(fb), with a sensitivity of 80% and a specificity of 88.2%.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.