m+Medelevator.RU
← Поиск публикаций
Brazilian journal of otorhinolaryngology · 2023

Effect of tinnitus on sound localization ability in patients with normal hearing.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Long Yue, Wang Wei, Liu Jiao, Liu Ke, Gong Shusheng

Аннотация

OBJECTIVES: To determine whether tinnitus negatively impacts the accuracy of sound source localization in participants with normal hearing.

METHODS: Seventy-five participants with tinnitus and 74 without tinnitus were enrolled in this study. The accuracy of sound source discrimination on the horizontal plane was compared between the two participant groups. The test equipment consisted of 37 loudspeakers arranged in a 180° arc facing forward with 5° intervals between them. The stimuli were pure tones of 0.25, 0.5, 1, 2, 4, and 8kHz at 50dB SPL. The stimuli were divided into three groups: low frequency (LF: 0.25, 0.5, and 1kHz), 2kHz, and high frequency (HF: 4 and 8kHz) stimuli.

RESULTS: The Root Mean Square Error (RMSE) score of all the stimuli in the tinnitus group was significantly higher than that in the control group (13.45±3.34 vs. 11.44±2.56, p=4.115, t<0.001). The RMSE scores at LF, 2kHz, and HF were significantly higher in the tinnitus group than those in the control group (LF: 11.66±3.62 vs. 10.04±3.13, t=2.918, p=0.004; 2kHz: 16.63±5.45 vs. 14.43±4.52, t=2.690, p=0.008; HF: 13.42±4.74 vs. 11.14 ±3.68, t=3.292, p=0.001). Thus, the accuracy of sound source discrimination in participants with tinnitus was significantly worse than that in those without tinnitus, despite the stimuli frequency. There was no difference in the ability to localize the sound of the matched frequency and other frequencies (12.86±6.29 vs. 13.87±3.14, t=1.204, p=0.236). Additionally, there was no correlation observed between the loudness of tinnitus and RMSE scores (r=0.096, p=0.434), and the Tinnitus Handicap Inventory (THI) and RMSE scores (r=-0.056, p=0.648).

CONCLUSIONS: Our present data suggest that tinnitus negatively impacted sound source localization accuracy, even when participants had normal hearing. The matched pitch and loudness and the impact of tinnitus on patients' daily lives were not related to the sound source localization ability.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты