American journal of audiology · 2023
Tinnitus Screener: Short-Term Test-Retest Reliability.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Thielman Emily J, Reavis Kelly M, Theodoroff Sarah M, Grush Leslie D, Thapa Samrita, Smith Brandon D, Schultz James, Henry James A
Аннотация
PURPOSE: The Tinnitus Screener was introduced in 2015 as a four-item algorithmic instrument to assess the temporal characteristics of a person's reported tinnitus. The Tinnitus Screener was then revised as a six-item version to include a new temporal category and to capture tinnitus duration (acute < 6 months vs. chronic ≥ 6 months). When contrasted with audiologist assessment, the four-item Tinnitus Screener was determined to be highly valid, but the short-term reliability of either version remained unknown. The present analysis focused on determining the test-retest reliability of the six-item Tinnitus Screener. Additionally, we sought to determine whether reliability differed by respondent age, sex, military status, and hearing loss.
METHOD: The Tinnitus Screener was administered to 190 military Service members and 250 military Veterans at two time points separated by 7-31 days. Our analysis focused on test-retest reliability of responses as measured by the kappa coefficient, overall and within subsamples. Percent agreement of tinnitus categorization (temporal categories) and classification (positive/negative) between the two time points was also evaluated.
RESULTS: Constant or intermittent tinnitus was found in 31% of Service members and 53% of Veterans. Overall, kappa reliability coefficients were high, near .80, indicating substantial reliability. The majority (96%) of reliability coefficients for the Tinnitus Screener within subsamples were similarly high, ranging from .68 to .88.
CONCLUSIONS: The updated version of the Tinnitus Screener is shown to be a reliable instrument. The Tinnitus Screener is recommended to inform clinical decision making by determining the temporal characteristics of tinnitus.
METHOD: The Tinnitus Screener was administered to 190 military Service members and 250 military Veterans at two time points separated by 7-31 days. Our analysis focused on test-retest reliability of responses as measured by the kappa coefficient, overall and within subsamples. Percent agreement of tinnitus categorization (temporal categories) and classification (positive/negative) between the two time points was also evaluated.
RESULTS: Constant or intermittent tinnitus was found in 31% of Service members and 53% of Veterans. Overall, kappa reliability coefficients were high, near .80, indicating substantial reliability. The majority (96%) of reliability coefficients for the Tinnitus Screener within subsamples were similarly high, ranging from .68 to .88.