MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jjcc.2025.06.022

Медицинская библиотека · Journal of cardiology · 2025

Valve in valve transcatheter versus redo surgical replacement of a failing surgical bioprosthetic aortic valve: An updated systematic review and meta-analysis.

Dimitriadis Kyriakos, Pyrpyris Nikolaos, Aznaouridis Konstantinos, Soulaidopoulos Stergios, Koutsopoulos Georgios, Beneki Eirini, Tatakis Fotis, Adamopoulou Eleni, Tsioufis Panagiotis, DeBiase Chiara, Milasinovic Dejan, De Backer Ole, Vanhaverbeke Maarten, Aggeli Konstantina, Tsioufis Konstantinos

СтатьяСистематический обзорМетаанализСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

With the aging population, degeneration of surgical aortic valves is an important clinical scenario. Currently, in most European countries, both redo surgery [redo-surgical aortic valve replacement (SAVR)] and valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) are established alternatives for treating such patients. This meta-analysis aims to compare redo-SAVR and ViV-TAVI for treating a failing bioprosthetic aortic valve.

METHODS

A systematic search was performed from inception to June 2023. After selecting all appropriate trials according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, a random effect meta-analysis was performed. Clinical and echocardiographic outcomes were compared among the groups.

RESULTS

Twenty-six studies with a total of population of 17,581 patients were included [ViV-TAVI (n = 9163) or redo-SAVR (n = 8418]. ViV-TAVI was associated with lower 30-day mortality (RR: 0.55; 95%CI: 0,47 to 0,66) and 1-year mortality (RR: 0.85; 95%CI: 0.75 to 0.96), major bleeding events (RR: 0.58; 95%CI: 0.42-0.79), and a trend towards lower new pacemaker implantations (RR: 0.70; 95%CI: 0.49-1.01) at 30 days. On the other hand, ViV-TAVI resulted in a higher mean transprosthetic gradient and higher rates of severe patient-prosthesis mismatch (RR: 1.64; 95%CI: 1.01 to 2.65) and paravalvular leak (RR: 2.44; 95%CI: 1.73-3.45) as compared to redo-SAVR. No significant difference was observed in 30-day myocardial infarction (RR: 0.90; 95%CI: 0.56 to 1.46) or stroke (RR: 0.77; 95%CI:0.55 to 1.06).

CONCLUSION

ViV-TAVI has a satisfying safety profile with better short-term survival outcomes as compared to redo-SAVR. However, adequate pre-procedural planning of VIV-TAVI cases is needed, in order to minimize the risk of a suboptimal hemodynamic outcomes following ViV-TAVI.

Для цитирования: Dimitriadis Kyriakos, Pyrpyris Nikolaos, Aznaouridis Konstantinos, Soulaidopoulos Stergios, Koutsopoulos Georgios, Beneki Eirini, Tatakis Fotis, Adamopoulou Eleni, Tsioufis Panagiotis, DeBiase Chiara, Milasinovic Dejan, De Backer Ole, Vanhaverbeke Maarten, Aggeli Konstantina, Tsioufis Konstantinos. Valve in valve transcatheter versus redo surgical replacement of a failing surgical bioprosthetic aortic valve: An updated systematic review and meta-analysis.. Journal of cardiology. 2025. DOI: 10.1016/j.jjcc.2025.06.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.