m+Medelevator.RU
← Поиск публикаций
European journal of applied physiology · 2026

Cigarette smoking slows the on- and the off- cardiorespiratory and gas-exchange kinetics during moderate exercise in young, physically active adults.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Borrelli Marta, Motalli Asia, Doria Christian, Toninelli Nicholas, Longo Stefano, Coratella Giuseppe, Cè Emiliano, Rampichini Susanna, Esposito Fabio

Аннотация

PURPOSE: Cigarette smoking (CS) impact on cardiopulmonary function has been extensively investigated on sedentary, middle-aged smokers (SMK) with pulmonary disease, but not on young SMK with high fitness level. This study evaluated the cardiopulmonary and gas-exchange kinetics during and after moderate exercise in young, physically active SM without known diseases.

METHODS: Ten SMK (age: 21 ± 2 year., body mass: 78 ± 6 kg; stature: 1.79 ± 0.07 m; 12 ± 5 cigarette/day for 6 ± 2 year.; mean ± SD) and twelve non-smokers (CTRL; age: 24 ± 3 year., body mass: 78 ± 9 kg; stature: 1.80 ± 0.08 m) matched also for exercise habits performed an incremental cycloergometric test to assess maximum pulmonary oxygen uptake ([Formula: see text]) and first ventilatory threshold (VT1). After pulmonary evaluation, participants performed four 6-min moderate-intensity tests at 90% VT1. The time constant (τ) of the on- and off-phases were determined for expiratory ventilation ([Formula: see text]), [Formula: see text] , heart rate (fH) and cardiac output ([Formula: see text]).

RESULTS: Despite similar static lung volumes, SMK exhibited lower peak expiratory flow (-21%; P = 0.009) and maximal voluntary ventilation (-12%; P = 0.008). SMK had lower [Formula: see text] (3657 ± 325 vs. 3397 ± 316 ml∙min− 1 for CTRL and SMK, respectively; P = 0.009) and mechanical power at VT1 (201 ± 26 vs. 185 ± 16 W for CTRL and SMK respectively; P = 0.041). In on-phase, SMK demonstrated longer τ in [Formula: see text] (+ 22%; P = 0.032), [Formula: see text] (+ 56%; P = 0.005), [Formula: see text] (+ 41%; P = 0.032), [Formula: see text] (+ 47%; P = 0.007) and. In off-phase, τ in SMK was lengthened for [Formula: see text] (+ 51%; P = 0.041), [Formula: see text] (+ 42%; P = 0.022), [Formula: see text] (+ 20%; P = 0.002) and [Formula: see text] (+ 42%; P = 0.018).

CONCLUSION: CS slowed cardiopulmonary and gas-exchange kinetics at moderate exercise even in young individuals with short smoking history.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты