OBJECTIVE

To evaluate the audiological aspects of vestibular schwannoma (VS) patients with normal hearing.

STUDY

DESIGN

Retrospective study.

SETTING

Quaternary referral center for skull base pathologies.

PATIENTS: The records on 4,000 patients who had been diagnosed with VS between 1986 and December 2017 were retrospectively reviewed. The patients included in the study were the ones who complied with the strict audiological normality criteria, as follows: a pure tone hearing threshold (at the 6-octave-spaced frequencies from 250 to 8,000 Hz) ≤25 dBHL; a word recognition score >90%; and interaural differences ≤10 dB at each frequency.

INTERVENTIONS: Auditory brainstem response (ABR) testing and radiological imaging.

MAIN OUTCOME MEASURES: The incidence of normal objective hearing among VS patients, and the diagnostic utility of the ABR and the effect of tumor size and site on the response.

RESULTS

The incidence of normal hearing among VS patients was 4.2%. Tinnitus and vertigo were the most common symptoms across tumor grades; 5.6% of the tumors were large and giant tumors. The ABR yielded a sensitivity of 73.6%, with a false negative rate of 26.3% using a cutoff point of 0.2 ms for interaural latency differences.

CONCLUSIONS

The diagnosis of VS should not be based on audiometric thresholds alone. Alarming signs of VS should be clear to the physician in order not to miss or delay the diagnosis of the disease. The ABR is useful in the diagnosis of VS, but normal results do not exclude the occurrence of the disease in patients with normal hearing.

Для цитирования: Salem Nervana, Galal Ahmed, Mastronardi Valentina, Talaat Mohamed, Sobhy Ossama, Sanna Mario. Audiological Evaluation of Vestibular Schwannoma Patients with Normal Hearing.. Audiology & neuro-otology. 2019. DOI: 10.1159/000500660.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.