Fluorescent Detection of Merlin-deficient Schwann Cells and Primary Human Vestibular Schwannoma Cells Using Sodium Fluorescein.

Perez Enrique R, Bracho Olena, Ein Liliana, Szczupak Mikhaylo, Monje Paula V, Fernandez-Valle Cristina, Alshaiji Abdulaziz, Ivan Michael, Morcos Jacques, Liu Xue-Zhong, Hoffer Michael, Eshraghi Adrien, Angeli Simon, Telischi Fred, Dinh Christine T

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

HYPOTHESIS: Merlin-deficient Schwann cells (MD-SC) and primary human vestibular schwannoma (VS) cells exhibit selective uptake of sodium-fluorescein (SF), allowing for fluorescent detection and improved visualization of tumor cells, when compared with Schwann cells (SC).

BACKGROUND

SF is a fluorescent compound used for fluorescence-guided resection of gliomas. The utility of SF for VS surgery has not been assessed.

METHODS

Mouse MD-SCs and rat SCs were cultured on 96-well plates at different cell densities and treated with SF at several drug concentrations and durations. Relative fluorescence units (RFU) were measured using a fluorometer to determine optimal treatment parameters in vitro. Subsequently, a four-point Likert scale for fluorescence visualization of pelleted cells was created and validated. Blinded observers rated SF-treated primary human VS and SC cultures, which were developed from deidentified specimens obtained from live and cadaveric donors, respectively.

RESULTS

In contrast to SCs that showed low levels of fluorescence, MD-SCs demonstrated dose-dependent increases in RFUs when treated with incremental dosages of SF as well as longer treatment and fluorescent excitation times. In addition, RFUs were higher at greater MD-SC densities. The Likert scale for fluorescence visualization was validated using nine blinded observers and there were excellent inter- and intrarater reliabilities (intraclass coefficients of 0.989 and >0.858, respectively). Using the Likert scale, human VS treated with SF received higher scores than human SCs (p < 0.001).

CONCLUSION

Mouse MD-SC and human VS cells demonstrate preferential uptake of SF when compared with normal primary SCs. Observers detected differences in fluorescence using the validated Likert scale. Further investigations into the utility of SF-guidance in VS surgery are warranted.

Для цитирования: Perez Enrique R, Bracho Olena, Ein Liliana, Szczupak Mikhaylo, Monje Paula V, Fernandez-Valle Cristina, Alshaiji Abdulaziz, Ivan Michael, Morcos Jacques, Liu Xue-Zhong, Hoffer Michael, Eshraghi Adrien, Angeli Simon, Telischi Fred, Dinh Christine T. Fluorescent Detection of Merlin-deficient Schwann Cells and Primary Human Vestibular Schwannoma Cells Using Sodium Fluorescein.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2018. DOI: 10.1097/mao.0000000000001895.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.