MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12659/msm.929445

Медицинская библиотека · Medical science monitor : international medical journal of experimental and clinical research · 2021

High-Resolution Magnetic Resonance Imaging (HR-MRI) Imaging Characteristics of Vertebral Artery Dissection with Negative MR Routine Scan and Hypoperfusion in Arterial Spin Labeling.

Zhang Yonggang, Miao Chongchang, Gu Yan, Jiang Shunbin, Xu Jian

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND Unruptured vertebral artery dissection (VAD) that causes ischemic infarction may require anticoagulant therapy or other treatments. However, anticoagulation therapy is not recommended for patients without ischemic infarction. To date, there has been no research on the imaging characteristics of patients with ischemic hypoperfusion that have a negative routine MRI scan. MATERIAL AND METHODS Patients with suspected VAD were recruited between June 2015 and June 2020 in order to perform high-resolution magnetic resonance imaging (HR-MRI). In total, 26 patients with negative MRI routine scans that underwent arterial spin labeling (ASL) examination were included in the study. The patients were divided into the hypoperfusion group and normal group based on whether hypoperfusion was found in ASL. The clinical features and HR-MRI features between these 2 groups were analyzed. RESULTS There were no statistical differences between the hypoperfusion group and normal group based on the patient's clinical characteristics (P>0.05). According to imaging characteristics between the 2 groups, the effective lumen index and the vertebrobasilar artery minimum angle were statistically significant (P.

Для цитирования: Zhang Yonggang, Miao Chongchang, Gu Yan, Jiang Shunbin, Xu Jian. High-Resolution Magnetic Resonance Imaging (HR-MRI) Imaging Characteristics of Vertebral Artery Dissection with Negative MR Routine Scan and Hypoperfusion in Arterial Spin Labeling.. Medical science monitor : international medical journal of experimental and clinical research. 2021. DOI: 10.12659/msm.929445.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.