MedElevator Войти в исследования
← Поиск публикаций

DOI 10.18240/ijo.2023.04.21

Медицинская библиотека · International journal of ophthalmology · 2023

Combined aqueous misdirection and persistent choroidal effusions following implantation of a Preserflo MicroShunt.

Malick Huzaifa, Wilde Craig, Stead Richard E

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To describe a case of aqueous misdirection complicated by subsequent persistent choroidal effusions following implantation of a Preserflo MicroShunt (PMS) device to treat advanced closed angle glaucoma.

METHODS

A 67-year-old caucasian female with advanced primary angle-closure glaucoma on four medications with an intraocular pressure (IOP) of 26 mm Hg was listed for a PMS insertion with mitomycin C (MMC).

RESULTS

Past ocular history was significant for pseudophakia and previous yttrium aluminum garnet (YAG) peripheral iridotomy. Surgery was uneventful but on the first postoperative day, she developed aqueous misdirection complicated by subsequent development of persistent uveal effusions. Conventional treatment strategies including atropine drops, YAG hyaloidotomy and choroidal effusion drainage proved ineffective. A combination of oral steroids and pars plana vitrectomy (PPV) along with an irido-zonulo-hyloidectomy (IZH) proved efficacious.

CONCLUSION

To the best of the author's knowledge, this is the first published case of aqueous misdirection complicated with the presence of significant, unresolving choroidal effusions, highlighting the possibility and sequelae of comorbid pathology in nanophthalmic eyes.

Для цитирования: Malick Huzaifa, Wilde Craig, Stead Richard E. Combined aqueous misdirection and persistent choroidal effusions following implantation of a Preserflo MicroShunt.. International journal of ophthalmology. 2023. DOI: 10.18240/ijo.2023.04.21.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.