Pediatric allergy and immunology : official publication of the European Society of Pediatric Allergy and Immunology · 2015
Prospective neonatal screening for severe T- and B-lymphocyte deficiencies in Seville.
СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
de Felipe Beatriz, Olbrich Peter, Lucenas José Manuel, Delgado-Pecellin Carmen, Pavon-Delgado Antonio, Marquez Josefina, Salamanca Carmen, Soler-Palacin Pere, Gonzalez-Granado Luis Ignacio, Antolin Laura Ferreras, Borte Stephan, Neth Olaf
Аннотация
BACKGROUND: Early diagnosis of primary immunodeficiency such as severe combined immunodeficiency (SCID) and X-linked agammaglobulinemia (XLA) improves outcome of affected children. T-cell-receptor-excision circles (TRECs) and kappa-deleting-recombination-excision circles (KRECs) determination from dried blood spots (DBS) identify neonates with severe T- and/or B-lymphopenia. No prospective data exist of the impact of gestational age (GA) and birth weight (BW) on TRECs and KRECs values.
METHODS: TRECs and KRECs determination using triplex RT-PCR (TRECS-KRECS-β-actin-Assay) from prospectively collected DBS between 02/2014 and 02/2015 in three hospitals in Seville, Spain. Cut-off levels were TRECs < 6/punch, KRECs < 4/punch and -β-actin>700/punch. Internal (SCID, XLA, ataxia telangiectasia) and external controls (NBS quality assurance program, CDC) were included.
RESULTS: A total of 5160 DBS were tested. Re-punch was needed in 77 samples (1.5%) due to insufficient β-actin (<700 copies/punch). Pre-term neonates (GA<37 weeks) and neonates with a BW<2500 g showed significantly lower TRECs and KRECs levels (p < 0.001). Due to repeat positive results five neonates were re-called (<0.1%): Fatal chromosomopathy (n = 1; TRECs 1/KRECs 4); extreme pre-maturity (n = 2; TRECs 0/KRECs 0 and TRECs 1/KRECs 20 copies/punch); neonates born to mothers receiving azathioprine during pregnancy (n = 2; TRECs 92/KRECs 1 and TRECs 154/KRECs 3 copies/punch). All internal and external controls were correctly identified.
CONCLUSIONS: TRECS-KRECS-β-actin-Assay correctly identifies T- and B-cell lymphopenias. Pre-maturity and low BW is associated with lower TREC and KREC levels. Extreme pre-maturity and maternal immune suppressive therapy may be a cause for false positive results of TRECs and KRECs values, respectively. To reduce the rate of insufficient samples, DBS extraction and storage need to be improved.
METHODS: TRECs and KRECs determination using triplex RT-PCR (TRECS-KRECS-β-actin-Assay) from prospectively collected DBS between 02/2014 and 02/2015 in three hospitals in Seville, Spain. Cut-off levels were TRECs < 6/punch, KRECs < 4/punch and -β-actin>700/punch. Internal (SCID, XLA, ataxia telangiectasia) and external controls (NBS quality assurance program, CDC) were included.
RESULTS: A total of 5160 DBS were tested. Re-punch was needed in 77 samples (1.5%) due to insufficient β-actin (<700 copies/punch). Pre-term neonates (GA<37 weeks) and neonates with a BW<2500 g showed significantly lower TRECs and KRECs levels (p < 0.001). Due to repeat positive results five neonates were re-called (<0.1%): Fatal chromosomopathy (n = 1; TRECs 1/KRECs 4); extreme pre-maturity (n = 2; TRECs 0/KRECs 0 and TRECs 1/KRECs 20 copies/punch); neonates born to mothers receiving azathioprine during pregnancy (n = 2; TRECs 92/KRECs 1 and TRECs 154/KRECs 3 copies/punch). All internal and external controls were correctly identified.
CONCLUSIONS: TRECS-KRECS-β-actin-Assay correctly identifies T- and B-cell lymphopenias. Pre-maturity and low BW is associated with lower TREC and KREC levels. Extreme pre-maturity and maternal immune suppressive therapy may be a cause for false positive results of TRECs and KRECs values, respectively. To reduce the rate of insufficient samples, DBS extraction and storage need to be improved.
Предметные рубрики MeSH
ArtifactsB-LymphocytesBirth WeightCase-Control StudiesDried Blood Spot TestingFalse Positive ReactionsFemaleGenetic MarkersGestational AgeHumansImmunologic Deficiency SyndromesInfant, Low Birth WeightInfant, NewbornInfant, PrematureLongitudinal StudiesMaleMultiplex Polymerase Chain ReactionNeonatal ScreeningPredictive Value of TestsProspective StudiesReal-Time Polymerase Chain ReactionReproducibility of ResultsRisk FactorsSeverity of Illness IndexSpainT-Lymphocytes