BACKGROUND

The population of patients with common variable immunodeficiency (CVID) comprises a heterogeneous group of patients with different causes of hypogammaglobulinemia predisposing to recurrent infections, higher incidence of autoimmunity, and malignancy. Although memory B cells (memBcs) are key players in humoral defense and their numbers are commonly reduced in these patients, their functionality is not part of any current classification.

OBJECTIVE

We established and validated a memBc enzyme-linked immunosorbent spot (ELISpot) assay that reveals the capacity of memBcs to develop into antibody-secreting cells and present an idea for a new classification based on this functional capacity.

METHODS

The memBc ELISpot assay, combined with flow cytometry, was applied to patients with confirmed CVID in comparison with age-matched healthy control subjects.

RESULTS

Ex vivo frequency of IgG-, IgM-, and IgA-secreting plasmablasts was significantly diminished by 27.2-, 2.4-, and 23.3-fold, respectively, compared with that seen in healthy control subjects. Moreover, in vitro differentiation of memBcs into antibody-secreting cells was 6.1-, 2.6-, and 3.7-fold significantly reduced for IgG-, IgM-, and IgA-secreting cells, respectively. Proliferation of memBcs correlates inversely to immunoglobulin-secreting capacity, suggesting compensatory hyperproliferation. Furthermore, patients with no serum IgA can still have a detectable IgA ELISpot assay result in vitro. Most importantly, the large heterogeneity of memBc function in patients with CVID homogenously grouped by means of fluorescence-activated cell sorting allowed additional subclassification based on memBc/plasmablast function.

CONCLUSION

These data suggest almost normal memBc/immunoglobulin-secreting plasmablast functionality in some patients if sufficient stimulatory signals are delivered, which might open up opportunities for new therapeutic approaches.

Для цитирования: Rösel Amelia L, Scheibenbogen Carmen, Schliesser Ulrike, Sollwedel André, Hoffmeister Bodo, Hanitsch Leif, von Bernuth Horst, Krüger Renate, Warnatz Klaus, Volk Hans-Dieter, Thomas Sybill. Classification of common variable immunodeficiencies using flow cytometry and a memory B-cell functionality assay.. The Journal of allergy and clinical immunology. 2014. DOI: 10.1016/j.jaci.2014.06.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.