MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arrct.2023.100308

Медицинская библиотека · Archives of rehabilitation research and clinical translation · 2023

A Pilot Feasibility Trial of an Upper Extremity Assistive System.

Hammelef Emma, Zakaria Saami J, Andersen Sarah H, Kelly Thomas J, Grampurohit Namrata, Avery Mikael, Napoli Alessandro, Mulcahey Mary Jane, Serruya Mijail Demian

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To develop and clinically evaluate a customizable active upper extremity (UE) assistive system with integrated functional electrical stimulation (FES) that improves function and independence of individuals during activities of daily living (ADLs).

DESIGN

Single-arm, prospective, open-label cohort feasibility trial.

SETTING

An academic research institution.

PARTICIPANTS

Subjects were 5 adults with a medical history of stroke resulting in distal UE impairment (N=5). The subjects volunteered from recruitment materials that detailed information about the study.

INTERVENTIONS: A novel, wearable, lightweight, low-profile, and patient-tailored UE assistive system. It comprises a splint component and FES unit that may each be controlled by electromyography (EMG) signals, inertial measurement units (IMUs), manual control source (joystick), and/or voice control.

MAIN OUTCOME MEASURES: Several occupational therapy outcome measures were used, including the Canadian Occupational Performance Measure (COPM), Action Research Arm Test (ARAT), The Box and Blocks Test (BBT), the ABILHAND-Manual Ability Measure, and Patient Reported Outcomes Measurement Information System (PROMIS) UE Short Form.

RESULTS

All participants learned to use our UE assistive system to perform ADLs and were able to use it independently at home. Most participants experienced a clinically meaningful improvement in both performance and satisfaction for the majority of their COPM goals while using the system. All participants experienced improvement in hand grip and release as shown by their baseline and post assessment scores for hand function (BBT, ARAT) and patient-reported outcomes (ABILHAND, PROMIS).

CONCLUSIONS

The clinical outcomes suggest that our UE assistive system improves functional performance in patients with UE impairment, allowing them to engage more actively in ADLs. Further innovation including elbow and shoulder components will allow users to have more degrees of freedom during tasks.

Для цитирования: Hammelef Emma, Zakaria Saami J, Andersen Sarah H, Kelly Thomas J, Grampurohit Namrata, Avery Mikael, Napoli Alessandro, Mulcahey Mary Jane, Serruya Mijail Demian. A Pilot Feasibility Trial of an Upper Extremity Assistive System.. Archives of rehabilitation research and clinical translation. 2023. DOI: 10.1016/j.arrct.2023.100308.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.