Evaluation of hearing loss after failed neonatal hearing screening.

Holster Ingrid L, Hoeve Lambertus J, Wieringa Marian H, Willis-Lorrier Rose M S, de Gier Henriette H W

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

We evaluated the causes of hearing loss found after failed universal newborn hearing screening and compared the results with the previously used behavioral observation test (Ewing/CAPAS).

STUDY

DESIGN

Hearing loss in neonates, born between September 1999 and October 2007 and referred to our center after failed screening, was determined by audiologic testing and physical examination.

RESULTS

In 340 included neonates the results of hearing tests were as follows: normal hearing 21.2%, conductive hearing loss 20.3%, and sensorineural hearing loss (SNHL) 57.9%. Children referred from the neonatal intensive care unit were more at risk of SNHL (71%) than those from the well-baby clinics (54%). Hearing aids were provided at a median age of 8 months. The positive predictive value of SNHL screening was 54% for a child from a well-baby clinic and 71% for a child from the neonatal intensive care unit.

CONCLUSION

The use of universal newborn hearing screening results in a lower proportion of infants positive because of otitis media with effusion than the previously used Ewing/CAPAS test (20% vs 59-81%). Second, screening leads to identification of hearing loss and intervention at a younger age (8 months vs 15-18 months). Third, the positive predictive value for SNHL has improved (54% vs 2%).

Для цитирования: Holster Ingrid L, Hoeve Lambertus J, Wieringa Marian H, Willis-Lorrier Rose M S, de Gier Henriette H W. Evaluation of hearing loss after failed neonatal hearing screening.. The Journal of pediatrics. 2009. DOI: 10.1016/j.jpeds.2009.05.003.