Journal of clinical medicine · 2026
Impact of Myopia Control Spectacle Lenses on Visual Functions in Young Adults: A Comprehensive Evaluation.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Alanazi Muteb K, Alhazmi Mohammed, Alotaibi Wafa, Altoaimi Basal H, Alshetwi Alla I, Alanazi Niran A, Alotaibi Meshal D, Alqahtani Bader S, Almalki Rayan H, Liu Maria
Аннотация
Purpose: To evaluate the impact of a myopia control (MC) spectacle lens incorporating peripheral defocus on functional visual parameters compared to conventional single vision (SV) lenses. Methods: Thirty-nine young adults (age 21.1 ± 1.3 years; spherical equivalent -2.85 ± 2.8 D) participated in this single-session, within-subject crossover design. Distance and near LogMAR VA were assessed centrally and at 22° nasal and temporal off-axis. Distance contrast sensitivity (CS) was measured across five spatial frequencies (1.5-18 cpd) and the Area Under the Log CS Function (AULCSF) calculated. Retinal sensitivity was evaluated using automated static perimetry. Dynamic visual performance was assessed using a standardized video game platform. Outcomes were compared using repeated measures ANOVA or Wilcoxon signed-rank tests. Results: Central VA was comparable between lens types. MC lenses significantly reduced off-axis distance VA (nasal: 0.35 ± 0.15 LogMAR; temporal: 0.20 ± 0.14 LogMAR; both p < 0.001) and near VA (nasal: 0.72 ± 0.25 LogMAR; temporal: 0.34 ± 0.2 LogMAR; both p < 0.001). Off-axis AULCSF was significantly reduced with MC lenses (nasal: 12.07 ± 5.06 vs. 26.37 ± 5.00 units; temporal: 13.00 ± 6.93 vs. 27.14 ± 4.64 units; both p < 0.001), while central AULCSF remained similar between lens types (SV: 27.87 ± 5.04 vs. MC: 27.15 ± 5.02 units; p = 0.277). No significant differences were found for visual field indices (all p > 0.05). Video game accuracy was comparable between lenses, but task completion time was slower with MC lenses (20.71 ± 10.08 vs. 18.39 ± 6.65 s; p = 0.012). Conclusions: MC spectacle lenses preserve central VA, CS, and visual field sensitivity but induce significant off-axis VA and off-axis CS reductions. Dynamic visuomotor accuracy is maintained, though task completion speed is modestly reduced. These functional trade-offs should be considered when prescribing MC lenses.