MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001857

Медицинская библиотека · Journal of cataract and refractive surgery · 2026

Size exchange and vault response in posterior chamber phakic intraocular lens implantation: 12 years at a high-volume center.

Choi Hannuy, Ryu Ik Hee, Lee In Sik, Jung Hyunjean, Lee Chae Eun, Yoo Tae Keun, Eom Youngsub

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate vault change after implantable collamer lens (ICL) exchange and identify outcome predictors, emphasizing age effects.

SETTING

High-volume refractive surgery center, South Korea.

DESIGN

Single-center retrospective cohort.

METHODS

Records of ICL implantations (2013 to 2024) were reviewed. Eyes requiring exchange were classified upsizing, same-size, or downsizing. Primary outcome: 6-month vault change; secondary: endothelial cell density (ECD). Indications for exchange and age-vault relationships were assessed.

RESULTS

Of 22 739 eyes, 110 (0.48%) underwent exchange: upsizing 70, same-size 27, downsizing 13. Indications differed by group: downsizing for high vault (13/13, 100%); upsizing for low vault (24/70, 34.3%) or toric rotation (44/70, 62.9%); same-size for residual refraction (17/27, 63.0%) or toric status change (10/27, 37.0%). Upsizing increased vault from 311.6 ± 223.0 μm to 481.0 ± 278.6 μm (Δ +169.4 μm; P < .001), with smaller gains at age 35 years or older. Downsizing reduced vault from 1284.2 ± 240.7 μm to 539.1 ± 176.1 μm (Δ -745.1 μm; P < .001), restoring 12 of 13 eyes (92.3%) to a prespecified safe range. Same-size exchange produced a small decrease (Δ -62.8 μm; P = .043). Across upsizing and downsizing, older age is linked to vault reduction, yielding smaller gains after upsizing (P = .013) and larger decreases after downsizing (P = .017). ECD showed small but significant declines across all groups (P < .050).

CONCLUSIONS

Vault change after ICL exchange was strategy-dependent: downsizing reliably reduced excessive vault, same-size exchange produced minimal change, and upsizing yielded smaller gains that diminished with increasing age. ICL exchange requires careful planning that accounts for exchange strategy, preoperative vault, and patient age.

Для цитирования: Choi Hannuy, Ryu Ik Hee, Lee In Sik, Jung Hyunjean, Lee Chae Eun, Yoo Tae Keun, Eom Youngsub. Size exchange and vault response in posterior chamber phakic intraocular lens implantation: 12 years at a high-volume center.. Journal of cataract and refractive surgery. 2026. DOI: 10.1097/j.jcrs.0000000000001857.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.