European heart journal. Case reports · 2024
Optimal site of pacemaker lead implantation for persistent atrial standstill guided by electroanatomical mapping following a cox-maze procedure: a case report.
Клинический случайСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ujiro Sae, Yamashita Soichiro, Takemoto Makoto, Okuda Masanori
Аннотация
BACKGROUND: Atrial standstill is characterized by the absence of atrial activity. We report a case of a patient with extensive atrial fibrosis who underwent electrophysiologic study (EPS) and electroanatomical mapping (EAM) to identify surviving atrial sites amenable for pacemaker lead implantation.
CASE SUMMARY: A 72-year-old man with persistent atrial fibrillation (AF) and atrial functional mitral regurgitation/tricuspid regurgitation (MR/TR) underwent a Cox-Maze surgery, mitral and tricuspid valve repair, and biatrial plication. He was referred because of post-operative presyncope symptoms. Electrocardiography revealed atrial standstill and junctional rhythm (JR); however, EAM revealed that both atria were almost entirely scarred and isolated fibrillation in left pulmonary veins and coronary sinus. Junctional rhythm retrogradely conducted around an atrioventricular (AV) node and pacing at this area could conduct to the ventricle through the AV node. An atrial pacing lead was implanted at this area, which yielded a QRS wave similar to the own beat. However, the atrial lead voltage was quite low; hence, ventricular pacing lead was implanted to avoid a future occurrence of pacing failure.
DISCUSSION: This report demonstrates the benefits of EPS and EAM in informing optimal pacemaker implantation for patients with extensive scar in atrium.
CASE SUMMARY: A 72-year-old man with persistent atrial fibrillation (AF) and atrial functional mitral regurgitation/tricuspid regurgitation (MR/TR) underwent a Cox-Maze surgery, mitral and tricuspid valve repair, and biatrial plication. He was referred because of post-operative presyncope symptoms. Electrocardiography revealed atrial standstill and junctional rhythm (JR); however, EAM revealed that both atria were almost entirely scarred and isolated fibrillation in left pulmonary veins and coronary sinus. Junctional rhythm retrogradely conducted around an atrioventricular (AV) node and pacing at this area could conduct to the ventricle through the AV node. An atrial pacing lead was implanted at this area, which yielded a QRS wave similar to the own beat. However, the atrial lead voltage was quite low; hence, ventricular pacing lead was implanted to avoid a future occurrence of pacing failure.
DISCUSSION: This report demonstrates the benefits of EPS and EAM in informing optimal pacemaker implantation for patients with extensive scar in atrium.