MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.16373

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2024

An artificial intelligence-enabled electrocardiogram algorithm for the prediction of left atrial low-voltage areas in persistent atrial fibrillation.

Tao Yirao, Zhang Deyun, Tan Chen, Wang Yanjiang, Shi Liang, Chi Hongjie, Geng Shijia, Ma Zhimin, Hong Shenda, Liu Xing Peng

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

We aimed to construct an artificial intelligence-enabled electrocardiogram (ECG) algorithm that can accurately predict the presence of left atrial low-voltage areas (LVAs) in patients with persistent atrial fibrillation.

METHODS

The study included 587 patients with persistent atrial fibrillation who underwent catheter ablation procedures between March 2012 and December 2023 and 942 scanned images of 12-lead ECGs obtained before the ablation procedures were performed. Artificial intelligence-based algorithms were used to construct models for predicting the presence of LVAs. The DR-FLASH and APPLE clinical scores for LVA prediction were calculated. We used a receiver operating characteristic (ROC) curve, calibration curve, and decision curve analysis to evaluate model performance.

RESULTS

The data obtained from the participants were split into training (n = 469), validation (n = 58), and test sets (n = 60). LVAs were detected in 53.7% of all participants. Using ECG alone, the deep learning algorithm achieved an area under the ROC curve (AUROC) of 0.752, outperforming both the DR-FLASH score (AUROC = 0.610) and the APPLE score (AUROC = 0.510). The random forest classification model, which integrated a probabilistic deep learning model and clinical features, showed a maximum AUROC of 0.759. Moreover, the ECG-based deep learning algorithm for predicting extensive LVAs achieved an AUROC of 0.775, with a sensitivity of 0.816 and a specificity of 0.896. The random forest classification model for predicting extensive LVAs achieved an AUROC of 0.897, with a sensitivity of 0.862, and a specificity of 0.935.

CONCLUSION

The deep learning model based exclusively on ECG data and the machine learning model that combined a probabilistic deep learning model and clinical features both predicted the presence of LVAs with a higher degree of accuracy than the DR-FLASH and the APPLE risk scores.

Для цитирования: Tao Yirao, Zhang Deyun, Tan Chen, Wang Yanjiang, Shi Liang, Chi Hongjie, Geng Shijia, Ma Zhimin, Hong Shenda, Liu Xing Peng. An artificial intelligence-enabled electrocardiogram algorithm for the prediction of left atrial low-voltage areas in persistent atrial fibrillation.. Journal of cardiovascular electrophysiology. 2024. DOI: 10.1111/jce.16373.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.