MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2023.11.027

Медицинская библиотека · JACC. Clinical electrophysiology · 2024

Efficiency and Durability of EIVOM on Acute Reconnection After Mitral Isthmus Bidirectional Block.

Zuo Song, Sang Caihua, Long Deyong, Bo Xiaowen, Lai Yiwei, Guo Qi, Wang Yufeng, Li Mengmeng, He Liu, Zhao Xin, Guo Xueyuan, Liu Nian, Li Songnan, Wang Wei, Jiang Chenxi, Tang Ribo, Du Xin, Dong Jianzeng, Ma Changsheng

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Reconnection after mitral isthmus (MI) block with radiofrequency ablation is common.

OBJECTIVES

The aim of this study was to investigate the effects of ethanol infusion in the vein of Marshall (EIVOM) on acute reconnection after MI bidirectional block.

METHODS

Patients with persistent atrial fibrillation who were scheduled to receive radiofrequency ablation for the first time were randomly assigned to the radiofrequency catheter ablation (RFCA) group (n = 44) or the EIVOM group (n = 45). The RFCA group's strategy was bilateral pulmonary vein ablation and linear ablation; in the EIVOM group, EIVOM was performed first. The primary endpoint was acute reconnection 30 minutes after MI bidirectional block.

RESULTS

A total of 89 patients (average age 62.9 years; 57.3% male) were enrolled. The average duration for persistent atrial fibrillation was 2.3 years. Before observation, all patients in the EIVOM group achieved MI bidirectional block (45 of 45 [100%]), compared with 84.1% (37 of 44) in the RFCA group. After the observation, 3 cases of MI reconnection occurred in the EIVOM group and 13 cases in the RFCA group (6.7% vs 35.1%; P < 0.05). After additional ablation, the final MI block rates in the EIVOM and RFCA groups were 97.8% (44 of 45) and 72.7% (32 of 44), respectively. During a 1-year follow-up, 8 of 45 patients who underwent EIVOM had recurrent atrial fibrillation, compared with 14 of 44 in the RFCA group (17.8% vs 31.8%; P < 0.01).

CONCLUSIONS

EIVOM can reduce acute reconnection after MI bidirectional block and significantly increase first-pass MI block.

Для цитирования: Zuo Song, Sang Caihua, Long Deyong, Bo Xiaowen, Lai Yiwei, Guo Qi, Wang Yufeng, Li Mengmeng, He Liu, Zhao Xin, Guo Xueyuan, Liu Nian, Li Songnan, Wang Wei, Jiang Chenxi, Tang Ribo, Du Xin, Dong Jianzeng, Ma Changsheng. Efficiency and Durability of EIVOM on Acute Reconnection After Mitral Isthmus Bidirectional Block.. JACC. Clinical electrophysiology. 2024. DOI: 10.1016/j.jacep.2023.11.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.