High power custom toric intraocular lens for correcting high corneal astigmatism in post-keratoplasty and keratoconus patients with cataract.

Reddy J K, Pooja C M, Prabhakar G V

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To analyze the outcomes of phacoemulsification with high power customized toric intraocular lens implantation (IOL) in patients with high corneal astigmatism (6-10 D Cyl) post keratoplasty and keratoconus eyes with cataract.

METHODS

Five eyes post keratoplasty with clear graft, four eyes with stable keratoconus, one eye with pterygium excision scar with visually significant cataract were included in this retrospective study. Phacoemulsification was done followed by implantation of custom made high power toric IOL in all patients. Outcomes included uncorrected and best-corrected distance visual acuity (UDVA, BCVA), pre-operative astigmatism at the corneal plane and IOL plane, post-operative residual astigmatism, mean torus of all IOLs used were calculated.

RESULTS

The minimum follow-up time was 12 months. At the last follow-up visit, there was a significant improvement (pre-operative vs post-operative) of UDVA (1.5 ± 0.47 vs 0.28 ± 0.14 logMAR; P < 0.05), cylindrical refraction (-9.0 ± 1.80 D vs -1.1 ± 0.45 vs ; P < 0.05). Range of IOL powers used was 1.0-26.50 DSph and 9.0-15.5 DCyl. Post-operative mean residual spherical equivalent was 0.75 ± 0.5.

CONCLUSION

This novel study describes the effectiveness of custom toric IOLs in high astigmatism in the range of 9.0-15.5 DCyl. Phacoemulsification with implantation of a customized high power toric IOL was effective in correcting high astigmatism in complex cases in our study.

Для цитирования: Reddy J K, Pooja C M, Prabhakar G V. High power custom toric intraocular lens for correcting high corneal astigmatism in post-keratoplasty and keratoconus patients with cataract.. Indian journal of ophthalmology. 2021. DOI: 10.4103/ijo.ijo_2640_20.