The British journal of ophthalmology · 2020
Proposal and validation of a new grading system for pterygium (SLIT2).
СтатьяВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ting Darren Shu Jeng, Liu Yu-Chi, Patil Moushmi, Ji Angel Jung Se, Fang Xiao Ling, Tham Yih Chung, Lee Yi-Fang, Htoon Hla M, Mehta Jodhbir S
Аннотация
BACKGROUND/AIMS: To propose and validate a new pterygium grading system based on slit-lamp evaluation.
METHODS: This prospective cross-sectional study included 217 patients with pterygium. All patients underwent slit-lamp examination, and slit-lamp photographs were independently graded by two graders twice. A total of eight parameters were evaluated and all parameters were assigned with a score of 1-4 (normal-severe). Intra-rater and inter-rater reliability as determined by weighted Cohen's kappa analysis.
RESULTS: A total of 868 independent assessment, based on 217 slit-lamp images, were performed by two graders. For conjunctival assessment, the intra-rater reliability was excellent for body thickness (κ=0.81-0.89) and size at limbus (κ=0.87-0.92), substantial-to-excellent for body vascularity (κ=0.72-0.86), and moderate-to-excellent for body length (κ=0.57-0.81), whereas the inter-rater reliability was excellent for size at limbus (κ=0.86), substantial for body thickness (κ=0.72-0.73) and body vascularity (κ=0.66-0.75), and moderate for body length (κ=0.54-0.57). For corneal assessment, the intra-rater reliability was excellent for all four parameters (κ=0.84-0.90) whereas the inter-rater reliability was excellent for head length (κ=0.86-0.87), substantial-to-excellent for head vascularity (κ=0.78-0.82), substantial for Stocker's line (κ=0.79-0.80) and head thickness (κ=0.67-0.69). The grading system was named SLIT2, which included S tocker's line, S ize at limbus, L ength of head/body, I njection/vascularity of body/head, and T hickness of body/head.
CONCLUSION: The proposed SLIT2 grading system, consisting of eight components, may serve as a reliable tool to standardise the reporting of pterygium severity and disease recurrence for clinical and research applications.
METHODS: This prospective cross-sectional study included 217 patients with pterygium. All patients underwent slit-lamp examination, and slit-lamp photographs were independently graded by two graders twice. A total of eight parameters were evaluated and all parameters were assigned with a score of 1-4 (normal-severe). Intra-rater and inter-rater reliability as determined by weighted Cohen's kappa analysis.
RESULTS: A total of 868 independent assessment, based on 217 slit-lamp images, were performed by two graders. For conjunctival assessment, the intra-rater reliability was excellent for body thickness (κ=0.81-0.89) and size at limbus (κ=0.87-0.92), substantial-to-excellent for body vascularity (κ=0.72-0.86), and moderate-to-excellent for body length (κ=0.57-0.81), whereas the inter-rater reliability was excellent for size at limbus (κ=0.86), substantial for body thickness (κ=0.72-0.73) and body vascularity (κ=0.66-0.75), and moderate for body length (κ=0.54-0.57). For corneal assessment, the intra-rater reliability was excellent for all four parameters (κ=0.84-0.90) whereas the inter-rater reliability was excellent for head length (κ=0.86-0.87), substantial-to-excellent for head vascularity (κ=0.78-0.82), substantial for Stocker's line (κ=0.79-0.80) and head thickness (κ=0.67-0.69). The grading system was named SLIT2, which included S tocker's line, S ize at limbus, L ength of head/body, I njection/vascularity of body/head, and T hickness of body/head.
CONCLUSION: The proposed SLIT2 grading system, consisting of eight components, may serve as a reliable tool to standardise the reporting of pterygium severity and disease recurrence for clinical and research applications.