m+Medelevator.RU
← Поиск публикаций
Annals of surgery · 2026

Diagnosing Lymphedema After Axillary Surgery: A Prospective Comparison of Bioimpedance, Tape Measurement, and Perometer in Patients Treated with Axillary Lymph Node Dissection.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Barrio Andrea V, Diskin Brian, Axelrod Bayley, Sevilimedu Varadan, Mehrara Babak, Morrow Monica

Аннотация

OBJECTIVE: This study prospectively compared lymphedema rates with perometer, tape measure, and bioimpedance spectroscopy (L-Dex) in patients with breast cancer undergoing axillary lymph node dissection (ALND).

BACKGROUND: Perometer, tape measure, and L-Dex are all used for diagnosing lymphedema, although lymphedema rates may vary between these techniques.

METHODS: From November 2016 to March 2020, patients who underwent ALND had arm measurements performed preoperatively and biannually with perometer, tape measure, and L-Dex. A lymphedema diagnosis was made if arm volume increased by ≥10% by perometer or tape measure, or if L-Dex increased ≥6.5 units from baseline. We assessed concordance between the different measurement techniques using scatter plots, Pearson correlations, and Cohen's Kappa statistic.

RESULTS: We included 281 patients who underwent ALND and had at least one follow-up (median, 2.3 years; >1100 follow-up measurements). Two-year lymphedema rates were 21.9% with perometer, 34.6% with tape measure, and 67.5% with L-Dex. Evaluating all timepoints, we found moderate correlation between perometer and tape measure (R=0.67, P<0.001), perometer and L-Dex (R=0.66, P<0.001) and tape measure and L-Dex (R=0.57, P<0.001). Diagnostic agreement was weak between perometer and L-Dex (k=0.29, P<0.001), and tape measure and L-Dex (k=0.28, P<0.001); and moderate between perometer and tape measure (k=0.51, P<0.001).

CONCLUSION: In our prospective ALND cohort, perometer, tape measure, and L-Dex demonstrated moderate correlation between measurements, and weak-to-moderate diagnostic agreement. Lymphedema rates varied between measurement techniques, with the highest rates observed with L-Dex, raising concern for overdiagnosis.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты