MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/a-2780-6493

Медицинская библиотека · Archives of plastic surgery · 2026

Validity of Ultrasound-Guided Identification of Dilated Lymphatic Vessels to Detect Early Breast Cancer-Related Lymphedema.

Hayashi Akitatsu, Fuziwara Takeo

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Early detection of breast cancer-related lymphedema (BCRL) is critical for timely intervention and preventing progression, but diagnostic modalities are limited. We assessed the validity of ultrasound-guided identification of dilated lymphatic vessels (UIDL) to detect early BCRL.

METHODS

A retrospective, observational study with 300 female patients evaluated for suspected BCRL in a lymphedema center between April 2019 and March 2023. All patients underwent gold standard to detect BCRL, indocyanine green (ICG) lymphography, staged by the MD Anderson grading system, and UIDL from the proximal one-third of the upper arm to the distal one-third of the forearm circumferentially. The association between UIDL, with a cutoff of ≥0.5 mm in diameter, and the detection of early BCRL by ICG lymphography was evaluated.

RESULTS

In total, 264 (88%) cases were detected as BCRL by ICG lymphography. UIDL's area under the curve was 0.89 (95% CI: 0.84-0.94), with sensitivity of 86.2%, specificity of 91.7%, positive predictive value of 98.4%, and negative predictive value of 53.2%.

CONCLUSION

UIDL showed high sensitivity and specificity in detecting early BCRL. This method may serve as a widely available, non-invasive screening tool during posttreatment surveillance.

Для цитирования: Hayashi Akitatsu, Fuziwara Takeo. Validity of Ultrasound-Guided Identification of Dilated Lymphatic Vessels to Detect Early Breast Cancer-Related Lymphedema.. Archives of plastic surgery. 2026. DOI: 10.1055/a-2780-6493.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.