DOI 10.1016/j.neulet.2022.137026

Медицинская библиотека · Neuroscience letters · 2022

One way or another: Treatment effects of 1 Hz rTMS using different current directions in a small sample of tinnitus patients.

Schoisswohl Stefan, Langguth Berthold, Weber Franziska C, Abdelnaim Mohamed A, Hebel Tobias, Mack Wolfgang, Schecklmann Martin

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

So far studies on the efficacy of repetitive transcranial magnetic stimulation (rTMS) as a treatment for tinnitus are inconclusive. Two large scale placebo-controlled randomized clinical trials (RCT) examined the efficacy of low frequency temporal cortex rTMS and report different findings. As the used TMS devices differ in their used primary current direction by default, this technical parameter was speculated as a potential reason for the observed incongruences in tinnitus-related outcomes. The aim of the present pilot study was to investigate the treatment effect of 1 Hz rTMS using two different current flows.

MATERIALS AND

METHODS

Nine tinnitus patients were treated in two different groups each comprised of 10 treatment sessions á 3000 biphasic pulses of 1 Hz rTMS applied over the left temporo-parietal cortex using either an anterior-posterior to posterior-anterior (AP-PA) or posterior-anterior to anterior-posterior (PA-AP) induced current flow.

RESULTS

1 Hz rTMS with a primary posterior-anterior to anterior-posterior (PA-AP) current flow caused a superior reduction in tinnitus-related symptoms, particularly tinnitus unpleasantness, loudness and tinnitus-related distress.

CONCLUSIONS

The present pilot study demonstrated that the technical TMS parameter current direction might be essential for the efficacy of rTMS as a treatment for tinnitus. Systematic investigations of technical TMS parameters like current direction in larger samples of tinnitus patients are highly needed.

Для цитирования: Schoisswohl Stefan, Langguth Berthold, Weber Franziska C, Abdelnaim Mohamed A, Hebel Tobias, Mack Wolfgang, Schecklmann Martin. One way or another: Treatment effects of 1 Hz rTMS using different current directions in a small sample of tinnitus patients.. Neuroscience letters. 2022. DOI: 10.1016/j.neulet.2022.137026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.