m+Medelevator.RU
← Поиск публикаций
Trends in hearing · 2022

Analysis of a Cochlear Implant Database: Changes in Tinnitus Prevalence and Distress After Cochlear Implantation.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Assouly Kelly K S, Smit Adriana L, Eikelboom Robert H, Sucher Cathy, Atlas Marcus, Stokroos Robert J, Stegeman Inge

Аннотация

The aim of this study was to estimate the prevalence and distress of tinnitus pre- and post-cochlear implantation in patients with bilateral severe to profound hearing loss. In this retrospective study, we included patients from a cochlear implant clinic in Perth, Western Australia. Pre- and post-cochlear implantation data from 300 implant recipients were collected on self-reported presence of tinnitus, tinnitus distress using the Tinnitus Reaction Questionnaire (TRQ), hearing-related quality of life using the Abbreviated Profile of Hearing Aid Benefit (APHAB), and consonant-nucleus vowel-consonant (CNC) word recognition test scores. Retrospectively, patients were grouped into those with or without tinnitus, and the grade of tinnitus distress. The potential factors associated with post-implantation changes in the presence of tinnitus and its distress were evaluated. Tinnitus prevalence was 55.8% pre-operatively and 44.3% post-implantation with a median TRQ score respectively of 12.0 (IQR: 1.0-28.0) and 3.5 (IQR: 0.0-16.2) points. Among the 96 patients experiencing tinnitus pre-implantation, 14.6% patients experienced moderate to catastrophic tinnitus distress pre-implantation compared to 6.3% post-implantation. To conclude, the pre- and post-implantation median TRQ score for the cohort population showed that tinnitus was a "slight" handicap. Tinnitus prevalence and its associated tinnitus distress decreased post-implantation. Patients with tinnitus post-implantation were significantly younger and had less severe pre-implantation hearing loss in the non-implanted ear than patients without tinnitus. Further research is needed to understand the factors influencing changes in tinnitus.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты