Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2005
A membrane model of electrically remodelled atrial myocardium derived from in vivo measurements.
СтатьяПоддержка NIH: внешняя программаПоддержка правительства СШАПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Goodman Amy M, Oliver Robert A, Henriquez Craig S, Wolf Patrick D
Аннотация
AIMS: Contemporary ionic-based membrane models are computationally expensive and are not intended to match the properties of a given experimental preparation. The aim of this work was to use measured restitution properties of electrically remodelled atrial tissue to develop a simplified membrane model based on the Fenton-Karma (FK) equations amenable to large-scale simulation of chronic atrial fibrillation (CAF).
METHODS: Two membrane models, the FK-CAF and FK-CNTRL parameter sets, were developed to match action potential duration (APD) and conduction velocity (CV) restitution properties of rapid-pacing-induced electrically remodelled sheep atria and healthy atria, respectively. The models were tested by inducing reentry in a two-dimensional anisotropic monodomain and comparing the resulting cycle lengths (CL) with measured CLs.
RESULTS: Parameters for the FK models were obtained that reproduced APD and CV restitution properties measured in the CAF and healthy sheep atria. Using the FK-CAF parameters, reentry was sustained in a 2.5 by 2.5 cm sheet with a CL = 91.0 +/- 3.0 ms. Reentry (CL = 113.2 +/- 5.2 ms) could only be sustained in the FK-CNTRL model after the tissue was first activated at a fast rate (136.5 ms).
CONCLUSIONS: The FK-CAF model is shown to approximate the restitution properties of remodelled sheep atria and can be used to simulate reentry with short CLs similar to those measured during AF episodes.
METHODS: Two membrane models, the FK-CAF and FK-CNTRL parameter sets, were developed to match action potential duration (APD) and conduction velocity (CV) restitution properties of rapid-pacing-induced electrically remodelled sheep atria and healthy atria, respectively. The models were tested by inducing reentry in a two-dimensional anisotropic monodomain and comparing the resulting cycle lengths (CL) with measured CLs.
RESULTS: Parameters for the FK models were obtained that reproduced APD and CV restitution properties measured in the CAF and healthy sheep atria. Using the FK-CAF parameters, reentry was sustained in a 2.5 by 2.5 cm sheet with a CL = 91.0 +/- 3.0 ms. Reentry (CL = 113.2 +/- 5.2 ms) could only be sustained in the FK-CNTRL model after the tissue was first activated at a fast rate (136.5 ms).
CONCLUSIONS: The FK-CAF model is shown to approximate the restitution properties of remodelled sheep atria and can be used to simulate reentry with short CLs similar to those measured during AF episodes.