m+Medelevator.RU
← Поиск публикаций
Biophysical journal · 2005

Ionic determinants of functional reentry in a 2-D model of human atrial cells during simulated chronic atrial fibrillation.

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Pandit Sandeep V, Berenfeld Omer, Anumonwo Justus M B, Zaritski Roman M, Kneller James, Nattel Stanley, Jalife José

Аннотация

Recent studies suggest that atrial fibrillation (AF) is maintained by fibrillatory conduction emanating from a small number of high-frequency reentrant sources (rotors). Our goal was to study the ionic correlates of a rotor during simulated chronic AF conditions. We utilized a two-dimensional (2-D), homogeneous, isotropic sheet (5 x 5 cm(2)) of human atrial cells to create a chronic AF substrate, which was able to sustain a stable rotor (dominant frequency approximately 5.7 Hz, rosette-like tip meander approximately 2.6 cm). Doubling the magnitude of the inward rectifier K(+) current (I(K1)) increased rotor frequency ( approximately 8.4 Hz), and reduced tip meander (approximately 1.7 cm). This rotor stabilization was due to a shortening of the action potential duration and an enhanced cardiac excitability. The latter was caused by a hyperpolarization of the diastolic membrane potential, which increased the availability of the Na(+) current (I(Na)). The rotor was terminated by reducing the maximum conductance (by 90%) of the atrial-specific ultrarapid delayed rectifier K(+) current (I(Kur)), or the transient outward K(+) current (I(to)), but not the fast or slow delayed rectifier K(+) currents (I(Kr)/I(Ks)). Importantly, blockade of I(Kur)/I(to) prolonged the atrial action potential at the plateau, but not at the terminal phase of repolarization, which led to random tip meander and wavebreak, resulting in rotor termination. Altering the rectification profile of I(K1) also slowed down or abolished reentrant activity. In combination, these simulation results provide novel insights into the ionic bases of a sustained rotor in a 2-D chronic AF substrate.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты