OBJECTIVE

This study aims to evaluate the effectiveness of Magnetic Resonance Virtual Endoscopy combined with 3D-FIESTA-c and 3D-TOF-MRA in preoperative assessment of MVD for PTN, with a focus on accurately detecting neuromuscular contact.

METHODS

We retrospectively analyzed clinical and imaging data from 240 patients with unilateral primary trigeminal neuralgia undergoing MVD surgery between April 2016 and July 2023. Preoperative scans with 3D-FIESTA-c and 3D-TOF-MRA were performed, and MRVE images were obtained to analyze the relationship between the trigeminal nerve and adjacent vessels. Using the findings during microvascular decompression (MVD) surgery as the gold standard, the diagnostic results of 3D-TOF-MRA + 3D-FIESTA-c were considered as group I, while the combined use of MRVE, 3D-TOF-MRA + 3D-FIESTA-c was considered as group II.

RESULTS

In 240 cases, group I had a positive rate of 96.25% and an accuracy rate of 86.25% for identifying responsible blood vessels, while group II had a positive rate of 98.3% and an accuracy rate of 94.17%. There were no statistically significant differences in positive rates between group I and group II, group I and MVD, or group II and MVD (P > 0.05). However, there were statistically significant differences in accuracy rates (P < 0.05). The accuracy for single and multiple arteries with group I was 99.38% and 80.0%, respectively, while with group II, it was 100% and 95.0%. No statistically significant difference was found in accuracy for single or multiple arteries (P>0.05). The accuracy of evaluating responsibility veins with or without other vessels was 52.73% and 80.0%, respectively, with a statistically significant difference (P<0.05).

CONCLUSION

MRVE combined with 3D-TOF-MRA + 3D-FIESTA-c significantly improves the accuracy of identifying responsibility vessels, especially veins, in preoperative assessment for MVD. This has important clinical implications for preoperative decision-making and surgical planning.

Для цитирования: Huang Yu, Huang Ying, Xiao Chaoyong, Huang Qingling, Chai Xue. Preoperative Evaluation of Neurovascular Relationship in Primary Trigeminal Neuralgia(PTN) by Magnetic Resonance Virtual Endoscopy(MRVE) Combined with 3D-FIESTA-c and 3D-TOF-MRA.. Journal of pain research. 2024. DOI: 10.2147/jpr.s465956.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.