MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12886-025-04095-8

Медицинская библиотека · BMC ophthalmology · 2025

Changes of corneal biomechanical and biometrical properties after combined phacoemulsification with viscocanalostomy surgery in patients with open-angle glaucoma.

Azimi Ali, Sadeghi Elham, Hassanipour Hamidreza, Bostanian Pardis, Attar Alireza, Eghtedari Dorna, Sharafi Zahra, Razmi Hooman, S Kumar Rajesh, Conner Ian

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To assess corneal biomechanical changes after phacoemulsification and ab-externo viscocanalostomy (phaco-visco) surgery in patients with open-angle glaucoma (OAG).

METHODS

Patients with OAG and cataract, visual acuity < 20/40 Snellen, were included. Pre- and postoperative evaluations were performed. Keratometric and aberrometry assessments were done with Oculus Pentacam AXL, and corneal biomechanics were evaluated using Corvis ST. Wilcoxon signed-rank and Chi-square tests were used.

RESULTS

This study included 30 eyes from 28 patients with OAG who underwent phaco-visco surgery. The mean age was 67.57 ± 9.20 years, with 50% being male. The mean postoperative follow-up duration was 4.1 ± 2.1 months. Postoperatively, biomechanically corrected intraocular pressure (bIOP) significantly decreased (-1.8 ± 4.7, P = 0.008), while central corneal thickness (CCT) showed no significant change (+ 0.333 ± 9.536, P = 0.810). Significant increases were observed in deflection amplitude max (+ 0.841 ± 0.173, P = 0.002), peak distance (+ 0.242 ± 0.458, P = 0.001), front astigmatism (+ 0.210 ± 0.420, P = 0.013), index of height asymmetry (+ 3.146 ± 6.374, P = 0.015), and index of height deviation (+ 0.007 ± 0.010, P = 0.001). Additionally, anterior chamber (AC) parameters such as AC depth (P = 0.001) and AC volume (P < 0.001) significantly increased following surgery.

CONCLUSIONS

This study shows that phaco-visco surgery in OAG eyes may increase corneal softening, decrease bIOP without altering CCT, induce corneal front astigmatism, and cause AC parameters changes. Corvis ST helps for more accurate IOP assessment and toric IOL planning.

Для цитирования: Azimi Ali, Sadeghi Elham, Hassanipour Hamidreza, Bostanian Pardis, Attar Alireza, Eghtedari Dorna, Sharafi Zahra, Razmi Hooman, S Kumar Rajesh, Conner Ian. Changes of corneal biomechanical and biometrical properties after combined phacoemulsification with viscocanalostomy surgery in patients with open-angle glaucoma.. BMC ophthalmology. 2025. DOI: 10.1186/s12886-025-04095-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.