Effect of 3.0 mm tunnel and 6.0 mm corneoscleral incisions on the blood-aqueous barrier.
Клиническое исследованиеСтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Diestelhorst M, Dinslage S, Konen W, Krieglstein G K
Аннотация
PURPOSE: To study of the effect of silicone intraocular lens (IOL) implantation using a 3.0 mm tunnel incision with that of implantation though a 6.0 mm corneoscleral incision after phacoemulsification in human eyes.
SETTING: Department of Ophthalmology, University of Köln, Germany.
METHODS: In a prospective, randomized clinical study, 50 patients with senile cataract had phacoemulsification and IOL implantation through a 3.0 mm tunnel or a 6.0 mm corneoscleral incision. To assess blood-aqueous barrier (BAB) disruption, preoperative and postoperative sodium fluorescein concentrations in the anterior chamber were measured with the Fluorotron Master II. Diclofenac sodium 0.1% was applied to the operative eyes five times a day for 5 days. The contralateral eyes served as controls.
RESULTS: There was no significant between-group difference in sodium fluorescein concentrations in the 5 days after surgery.
CONCLUSION: The findings underline our clinical impression that BAB disruption 5 days after surgery does not differ significantly with the type and length of scleral incision used for IOL implantation.
SETTING: Department of Ophthalmology, University of Köln, Germany.
METHODS: In a prospective, randomized clinical study, 50 patients with senile cataract had phacoemulsification and IOL implantation through a 3.0 mm tunnel or a 6.0 mm corneoscleral incision. To assess blood-aqueous barrier (BAB) disruption, preoperative and postoperative sodium fluorescein concentrations in the anterior chamber were measured with the Fluorotron Master II. Diclofenac sodium 0.1% was applied to the operative eyes five times a day for 5 days. The contralateral eyes served as controls.
RESULTS: There was no significant between-group difference in sodium fluorescein concentrations in the 5 days after surgery.
CONCLUSION: The findings underline our clinical impression that BAB disruption 5 days after surgery does not differ significantly with the type and length of scleral incision used for IOL implantation.