m+Medelevator.RU
← Поиск публикаций
Journal of clinical anesthesia · 2026

Use of smart glasses for ultrasound-guided central venous catheterization in adults: a randomized clinical trial.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wang Yuwen, Jiang Lingling, Wang Furui, Liu Ping, Xue Tingting, Zhang Rui, Zheng Zongqin, Wang Penglei, Zhang Ye, Wu Yun

Аннотация

BACKGROUND: Head-mounted displays can be integrated with ultrasonography to overlay the image in the operator's field of view, improving hand-eye coordination during invasive procedures. The clinical efficacy of smart glasses for central venous catheterization (CVC) remains uncertain. This study aimed to evaluate whether using smart glasses can improve efficiency compared to conventional ultrasound-guided CVC.

METHODS: This prospective, single-blinded, controlled study enrolled adult patients who underwent elective surgery requiring CVC. Patients were assigned to either the ultrasound screen (control) or smart glasses group using stratified randomization according to operator qualification. The primary outcome was the overall CVC procedural time. Secondary outcomes included ultrasound scanning and venous access time, number of needle redirections and probe repositionings, procedural success and complication rates.

RESULTS: In total, 124 patients were analyzed. The overall procedural time was significantly reduced in the smart glasses group compared to that in the control group (158 [140, 189] s vs. 134 [117,150] s; median difference, 26.0 s; 95% CI, [16.0-37.0] s, P < 0.001). Specifically, the ultrasound scanning time (median difference, 3.0 s, P = 0.004), venous access time (median difference, 2.0 s, P = 0.013), number of needle redirections (median difference, 1.0, P = 0.003) and probe repositionings (median difference, 0.0, P = 0.005) were significantly reduced in the smart glasses group compared to those in the control group. However, the success and complication rates were comparable between groups.

CONCLUSIONS: Smart glasses modestly improved procedural efficiency in ultrasound-guided CVC, potientially for novices, without improving success or complication rates. Larger-sample studies with more diverse operators and patients are warranted.

TRIAL REGISTRATION: Name of trial registry: ClinicalTrials.gov Registration number: NCT06469034 URL: https://clinicaltrials.gov/study/NCT06469034?id=NCT06469034&rank=1.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты