MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2019.07.014

Медицинская библиотека · Journal of cataract and refractive surgery · 2019

Defocus curves of 4 presbyopia-correcting IOL designs: Diffractive panfocal, diffractive trifocal, segmental refractive, and extended-depth-of-focus.

Böhm Myriam, Petermann Kerstin, Hemkeppler Eva, Kohnen Thomas

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the defocus curves of 4 presbyopia-correcting intraocular lenses (IOLs).

SETTING

Department of Ophthalmology, Goethe University, Frankfurt, Germany.

DESIGN

Prospective case series.

METHODS

Patients included in the study had bilateral surgery with implantation of diffractive panfocal, diffractive trifocal, segmental refractive (SegRef), or extended-depth-of-focus (EDOF) presbyopia-correcting IOLs. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, uncorrected intermediate and near visual acuities, distance-corrected intermediate (DCIVA) and near (DCNVA) visual acuities, defocus curve, and spectacle independence were measured.

RESULTS

The UDVA and CDVA were not significantly different between groups (P > .05); however, the EDOF group had worse near CDVA (P < .001). The trifocal and EDOF groups showed better DCIVA than the panfocal and SegRef group at 80 cm (P < .001); the EDOF and panfocal groups had comparable DCIVA at 60 cm (P > .05). Defocus curves showed no significant between-group differences from 4 m to 2 m (P > .05). The EDOF group had better visual acuity from 1 m to 67 cm than the trifocal and SegRef groups and better visual acuity than the panfocal group at 1 m (P > .05). Compared with the other IOLs, the panfocal IOL yielded significantly better visual acuity at 50 cm (P < .001) and the EDOF IOL worse visual acuity at 40 cm (P < .01). There was a significant difference in spectacle independence between the panfocal group and EDOF group (P < .05) but no difference between the other groups.

CONCLUSIONS

The 4 IOLs provided equally good CDVA. The EDOF IOL yielded slightly better DCIVA but worse DCNVA than the other IOLs. Only the panfocal IOL gave better DCIVA at 50 cm.

Для цитирования: Böhm Myriam, Petermann Kerstin, Hemkeppler Eva, Kohnen Thomas. Defocus curves of 4 presbyopia-correcting IOL designs: Diffractive panfocal, diffractive trifocal, segmental refractive, and extended-depth-of-focus.. Journal of cataract and refractive surgery. 2019. DOI: 10.1016/j.jcrs.2019.07.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.