MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0211823

Медицинская библиотека · PloS one · 2019

The Light Sword Lens - A novel method of presbyopia compensation: Pilot clinical study.

Petelczyc Krzysztof, Byszewska Anna, Chojnacka Ewelina, Jaroszewicz Zbigniew, Kakarenko Karol, Mira-Agudelo Alejandro, Ostrowska-Spaleniak Aleksandra, Składowska Aleksandra, Kołodziejczyk Andrzej, Rękas Marek

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Clinical assessment of a new optical element for presbyopia correction-the Light Sword Lens.

METHODS

Healthy dominant eyes of 34 presbyopes were examined for visual performance in 3 trials: reference (with lens for distance correction); stenopeic (distance correction with a pinhole ϕ = 1.25 mm) and Light Sword Lens (distance correction with a Light Sword Lens). In each trial, visual acuity was assessed in 7 tasks for defocus from 0.2D to 3.0D while contrast sensitivity in 2 tasks for defocus 0.3D and 2.5D. The Early Treatment Diabetic Retinopathy Study protocol and Pelli-Robson method were applied. Within visual acuity and contrast sensitivity results degree of homogeneity through defocus was determined. Reference and stenopeic trials were compared to Light Sword Lens results. Friedman analysis of variance, Nemenyi post-hoc, Wilcoxon tests were used, p-value < 0.05 was considered significant.

RESULTS

In Light Sword Lens trial visual acuity was stable in tested defocus range [20/25-20/32], Stenopeic trial exhibited a limited range of degradation [20/25-20/40]. Light Sword Lens and reference trials contrast sensitivity was high [1.9-2.0 logCS] for both defocus cases, but low in stenopeic condition [1.5-1.7 logCS]. Between-trials comparisons of visual acuity results showed significant differences only for Light Sword Lens versus reference trials and in contrast sensitivity only for Light Sword Lens versus stenopeic trials.

CONCLUSIONS

Visual acuity achieved with Light Sword Lens correction in presbyopic eye is comparable to stenopeic but exhibits none significant loss in contrast sensitivity. Such correction method seems to be very promising for novel contact lenses and intraocular lenses design.

Для цитирования: Petelczyc Krzysztof, Byszewska Anna, Chojnacka Ewelina, Jaroszewicz Zbigniew, Kakarenko Karol, Mira-Agudelo Alejandro, Ostrowska-Spaleniak Aleksandra, Składowska Aleksandra, Kołodziejczyk Andrzej, Rękas Marek. The Light Sword Lens - A novel method of presbyopia compensation: Pilot clinical study.. PloS one. 2019. DOI: 10.1371/journal.pone.0211823.