MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/2150135116670632

Медицинская библиотека · World journal for pediatric & congenital heart surgery · 2017

Sustained Improvement in Right Ventricular Chamber Dimensions 10 Years Following Xenograft Pulmonary Valve Replacement.

Schubmehl Heidi B, Swartz Michael F, Atallah-Yunes Nader, Wittlieb-Weber Carol, Pratt Rebecca E, Alfieris George M

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The goals following pulmonary valve replacement (PVR) are to optimize right ventricular hemodynamics and minimize the need for subsequent reoperations on the right ventricular outflow tract. We hypothesized PVR using a xenograft valved conduit would result in superior freedom from reoperation with sustained improvement in right ventricular chamber dimensions.

METHODS

Xenograft valved conduits placed in patients aged >16 years were reviewed from 2000 to 2010 to allow for a 5-year minimum follow-up. Preoperative, one-year, and the most recent echocardiograms quantified right ventricular chamber dimensions, corresponding Z scores, and prosthetic valve function. Magnetic resonance imaging (MRI) studies compared preoperative and follow-up right ventricular volumes.

RESULTS

A total of 100 patients underwent PVR at 24 (19-34) years. Freedom from reintervention was 100% at 10 years. At most recent follow-up, only one patient had greater than mild pulmonary insufficiency. The one-year (17.3 ± 7.2 mm Hg; P < .01) and most recent follow-up (18.6 ± 9.8 mm Hg; P < .01) Doppler-derived right ventricular outflow tract gradients remained significantly lower than preoperative measurements (36.7 ± 27.0 mm Hg). Similarly, right ventricular basal diameter, basal longitudinal diameter, and the corresponding Z scores remained lower at one year and follow-up from preoperative measurements. From 34 MRI studies, the right ventricular end-diastolic indexed volume (161.7 ± 58.5 vs 102.9 ± 38.3; P < .01) and pulmonary regurgitant fraction (38.0% ± 15.9% vs 0.8% ± 3.3%; P < .01) were significantly lower at 7.1 ± 3.4 years compared to the preoperative levels.

CONCLUSION

Use of a xenograft valved conduit for PVR results in excellent freedom from reoperation with sustained improvement in right ventricular dimensions at an intermediate-term follow-up.

Для цитирования: Schubmehl Heidi B, Swartz Michael F, Atallah-Yunes Nader, Wittlieb-Weber Carol, Pratt Rebecca E, Alfieris George M. Sustained Improvement in Right Ventricular Chamber Dimensions 10 Years Following Xenograft Pulmonary Valve Replacement.. World journal for pediatric & congenital heart surgery. 2017. DOI: 10.1177/2150135116670632.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.