DOI 10.1097/01.mlg.0000241365.54017.32
Hearing loss in rheumatoid arthritis.
Аннотация
OBJECTIVE
The objective of this study was to evaluate whether patients with rheumatoid arthritis (RA) are more likely to have subclinical hearing loss compared with persons without RA.
METHODS
This is a case-control cross-sectional study of 29 patients with RA with disease duration greater than 5 years. Five males and five females were recruited into each decade category (age 40-49, 50-59, and 60-69). These cases were matched in a 1:1 ratio by sex and age to 30 control subjects. A comprehensive set of audiometric and disease severity assessments were performed.
RESULTS
Seventeen (59%) of 29 patients with RA had abnormal hearing for at least one frequency (four in one ear, 13 in two ears) by audiometry as did 14 (47%) of 30 control subjects (five in one ear, nine in two ears). The percentage of patients with hearing loss (% RA vs. % control subjects) was: 45% versus 40% sensorineural, 10% versus 7% conductive, and 3% versus 0% mixed hearing loss. In RA versus control subjects, acoustic reflex threshold was abnormal in 17% versus 7%; speech reception threshold was abnormal in 10% versus 3%. Tympanometry and otoacoustic emission findings were similar in both groups. Word recognition did not differ between patients with RA and control subjects. In patients with RA/control subjects, hearing handicap, dizziness, and health assessment questionnaires were abnormal in 28%/7%, 14%/3%, and 72%/7%, respectively.
CONCLUSION
There was no difference found in objective audiometric measurements in patients with RA compared with non-RA control subjects. Subjectively patients with RA were more likely to perceive themselves as having hearing disturbances, which may be related to overall disease related functional impairment.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.