MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3967/bes2017.097

Медицинская библиотека · Biomedical and environmental sciences : BES · 2017

Rapid and Accurate Sequencing of Enterovirus Genomes Using MinION Nanopore Sequencer.

Wang Ji, Ke Yue Hua, Zhang Yong, Huang Ke Qiang, Wang Lei, Shen Xin Xin, Dong Xiao Ping, Xu Wen Bo, Ma Xue Jun

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Knowledge of an enterovirus genome sequence is very important in epidemiological investigation to identify transmission patterns and ascertain the extent of an outbreak. The MinION sequencer is increasingly used to sequence various viral pathogens in many clinical situations because of its long reads, portability, real-time accessibility of sequenced data, and very low initial costs. However, information is lacking on MinION sequencing of enterovirus genomes.

METHODS

In this proof-of-concept study using Enterovirus 71 (EV71) and Coxsackievirus A16 (CA16) strains as examples, we established an amplicon-based whole genome sequencing method using MinION. We explored the accuracy, minimum sequencing time, discrimination and high-throughput sequencing ability of MinION, and compared its performance with Sanger sequencing.

RESULTS

Within the first minute (min) of sequencing, the accuracy of MinION was 98.5% for the single EV71 strain and 94.12%-97.33% for 10 genetically-related CA16 strains. In as little as 14 min, 99% identity was reached for the single EV71 strain, and in 17 min (on average), 99% identity was achieved for 10 CA16 strains in a single run.

CONCLUSION

MinION is suitable for whole genome sequencing of enteroviruses with sufficient accuracy and fine discrimination and has the potential as a fast, reliable and convenient method for routine use.

Для цитирования: Wang Ji, Ke Yue Hua, Zhang Yong, Huang Ke Qiang, Wang Lei, Shen Xin Xin, Dong Xiao Ping, Xu Wen Bo, Ma Xue Jun. Rapid and Accurate Sequencing of Enterovirus Genomes Using MinION Nanopore Sequencer.. Biomedical and environmental sciences : BES. 2017. DOI: 10.3967/bes2017.097.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.