MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.eupc.2004.05.008

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2004

Typical atrial flutter ablation outcome: correlation with isthmus anatomy using intracardiac echo 3D reconstruction.

Scaglione Marco, Caponi Domenico, Di Donna Paolo, Riccardi Riccardo, Bocchiardo Mario, Azzaro Giuseppe, Leuzzi Stefano, Gaita Fiorenzo

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: To verify if sites of conduction gaps on the isthmus correlate with anatomical peculiarities using the intracardiac echo (ICE) and a new 3D device to reconstruct the isthmus in patients undergoing cavotricuspid isthmus ablation.

METHODS AND

RESULTS

Twenty patients underwent isthmus ablation using an 8 mm tip ablation catheter. Two-dimensional and 3D ICE reconstruction of the isthmus was made before, during and after ablation. At the end of the lesion line isthmus block was validated by electrophysiological criteria. In case of its absence we closed the remaining conduction gaps verifying the position of the sites with ICE. Fourteen patients required a median of 8 RF pulses to obtain complete isthmus block (Group A). In the remaining 6 patients isthmus block was obtained with a median of 25 RF pulses due to conduction gaps 'resistant' to ablation (Group B). Conduction gap positions assessed by ICE were located in the central portion of the isthmus below the coronary sinus os in 71% of cases in Group A and along a prominent Eustachian ridge in Group B patients, respectively. 3D reconstruction showed a smooth isthmus in Group A with a 'peak and valleys' isthmus in Group B. In these latter patients isthmus block was obtained only after the complete ablation of the prominent Eustachian ridge.

CONCLUSION

The isthmus presents anatomical variants particularly due to Eustachian ridge peculiarities which may represent a site of conduction gaps "resistant" to ablation.

Для цитирования: Scaglione Marco, Caponi Domenico, Di Donna Paolo, Riccardi Riccardo, Bocchiardo Mario, Azzaro Giuseppe, Leuzzi Stefano, Gaita Fiorenzo. Typical atrial flutter ablation outcome: correlation with isthmus anatomy using intracardiac echo 3D reconstruction.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2004. DOI: 10.1016/j.eupc.2004.05.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.