DOI 10.1161/01.cir.100.7.768

Медицинская библиотека · Circulation · 1999

Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter?

Tsai C F, Tai C T, Yu W C, Chen Y J, Hsieh M H, Chiang C E, Ding Y A, Chang M S, Chen S A

Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The prospective, randomized study comparing 4- with 8-mm tip electrodes for radiofrequency linear ablation of typical atrial flutter is not available.

METHODS AND

RESULTS

A total of 104 consecutive patients with typical atrial flutter were randomly assigned to undergo radiofrequency linear ablation using a 4- (Group I, n=54) or 8-mm tip electrode (Group II, n=50) catheter (temperature-control model, preset 70 degrees C). If complete bidirectional isthmus block could not be achieved after 5 pulses, the ablation catheter was changed to the other type; the maximal radiofrequency pulse number was limited to <10 pulses. Complete or incomplete isthmus conduction block was assessed by activation sequence in a multielectrode Halo catheter during low lateral right atrial and proximal coronary sinus pacing. Before shifting to the other catheter type, the 8-mm electrode catheter achieved higher complete isthmus block rate (92% versus 67%, P<0.05) with fewer pulses (2+/-1 versus 3+/-1, P<0.05), shorter procedure time (24+/-15 versus 31+/-12 minutes, P<0.05), and shorter fluoroscopic time (14+/-10 versus 23+/-15 minutes, P<0.05). After 5 failed ablation pulses, 12 (67%) of 18 patients in group I attained complete isthmus block by using an 8-mm tip catheter, but none of 4 patients in group II achieved complete block by changing to a 4-mm tip catheter.

CONCLUSIONS

The 8-mm tip electrodes are more effective than the standard 4-mm length electrodes in linear ablation for typical atrial flutter. This clinical benefit may be of particular value for some patients with broad and/or thick isthmus.

Для цитирования: Tsai C F, Tai C T, Yu W C, Chen Y J, Hsieh M H, Chiang C E, Ding Y A, Chang M S, Chen S A. Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter?. Circulation. 1999. DOI: 10.1161/01.cir.100.7.768.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.