MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/apm.12838

Медицинская библиотека · APMIS : acta pathologica, microbiologica, et immunologica Scandinavica · 2018

Design and construction of a new recombinant fusion protein (2b2t+EPC1) and its assessment for serodiagnosis of cystic echinococcosis.

Fathi Saeid, Jalousian Fatemeh, Hosseini Seyed Hossein, Najafi Ali, Darabi Enayat, Koohsar Faramarz

СтатьяПеревод пока не подготовлен

Аннотация

The immunodiagnostic tests for cystic echinococcosis (CE) are mostly serological tests based on ELISA that use hydatid cyst antigens for primary screening because of its simple preparation and availability. The challenge to develop new serological methods (as compared to those based on the hydatid cyst fluid antigens) to meet the gold standard remains. Appropriate sources of antigenic material are necessary for application to improve the efficacy of immunodiagnostic tests at a population level. In the current study, a fusion protein containing the coding sequence of antigen B2t and two sequences of EPC1 antigen with some modifications was reconstructed. Using bioinformatics tools, these sequences were joined together by applying the sequence of a rigid α-helix-forming linker to obtain an appropriate structure of a fusion protein. Synthetic recombinant fusion protein was expressed using pET28a as a vector and evaluated by indirect ELISA test for sera from patients with hepatic CE and other parasitic infections. The sensitivity of the fusion protein was lower (88.46%) than the available ELISA kit (96.15%). However, the differences in sensitivity were not statistically significant as compared to the recombinant fusion peptide with the commercial kit (p = 0.269). The specificity of the recombinant fusion protein (95.45%) was not significantly lower than the commercial kit (96.59%; p = 1.000). Moreover, surprisingly there was no difference in the cross-reactivity values of performance between the recombinant-ELISA and commercial kit. The positive and negative predictive values of the recombinant antigen were achieved as 92% and 93.33%, respectively, while for the commercial kit, they were obtained as 94.33% and 97.70%, respectively. In conclusion, as an early evaluation of these antigens the performance of our recombinant fusion protein in ELISA is relatively promising. Although, it seemed that this peptide with specific antigenic epitopes might be more appropriate for the serological evaluation of CE by use of bioinformatics tools, our findings showed that cross-reactions and a negative reaction could occur in clinical performance. This fusion protein may have utility for diagnosis in humans, but further evaluation is needed using the WHO ultrasound classification for CE.

Для цитирования: Fathi Saeid, Jalousian Fatemeh, Hosseini Seyed Hossein, Najafi Ali, Darabi Enayat, Koohsar Faramarz. Design and construction of a new recombinant fusion protein (2b2t+EPC1) and its assessment for serodiagnosis of cystic echinococcosis.. APMIS : acta pathologica, microbiologica, et immunologica Scandinavica. 2018. DOI: 10.1111/apm.12838.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.