MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/pep.0b013e318181ae96

Медицинская библиотека · Pediatric physical therapy : the official publication of the Section on Pediatrics of the American Physical Therapy Association · 2008

The test of infant motor performance: reliability in spinal muscular atrophy type I.

Finkel Richard S, Hynan Linda S, Glanzman Allan M, Owens Hollis, Nelson Leslie, Cone Stephanie R, Campbell Suzann K, Iannaccone Susan T, AmSMART Group

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this article was to determine reliability of the Test of Infant Motor Performance (TIMP) in infants with spinal muscular atrophy, type I (SMA-I).

METHODS

Interrater reliability training was undertaken by 17 physical therapist evaluators using 6 infants with hypotonia and weakness (5 videotaped, 1 live). Eight trained evaluators then conducted a test-retest reliability study at their own center, performing 2 tests approximately 1 month apart on each of 11 infants with genetically confirmed SMA-I (5 boys, 6 girls; age range 37-501 days; 3 on pulmonary support).

RESULTS

The interrater reliability training session had an overall weighted Kappa of 0.61 (95% confidence interval 0.59-0.63). For the test-retest reliability study, the intraclass correlation coefficient for the TIMP Total Score was 0.85 (95% confidence interval: 0.54-0.96). The test scores were not significantly different between the 2 sessions (Bradley-Blackwood test was nonsignificant).

CONCLUSION

TIMP scores can be reliably obtained in infants with SMA-I.

Для цитирования: Finkel Richard S, Hynan Linda S, Glanzman Allan M, Owens Hollis, Nelson Leslie, Cone Stephanie R, Campbell Suzann K, Iannaccone Susan T, AmSMART Group. The test of infant motor performance: reliability in spinal muscular atrophy type I.. Pediatric physical therapy : the official publication of the Section on Pediatrics of the American Physical Therapy Association. 2008. DOI: 10.1097/pep.0b013e318181ae96.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.