MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejcts.2010.02.014

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2010

Preservation of the pulmonary autograft after failure of the Ross procedure.

de Kerchove Laurent, Boodhwani Munir, Etienne Pierre-Yves, Poncelet Alain, Glineur David, Noirhomme Philippe, Rubay Jean, El Khoury Gebrine

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Failure of the pulmonary autograft following the Ross Procedure is mainly due to dilatation and/or cusp prolapse causing insufficiency. We analysed the result of pulmonary autograft valve sparing and repair, using techniques developed for native aortic root and valve.

METHODS

Of a total of 275 patients who underwent Ross operation between 1991 and 2009, 31 needed autograft re-operation. Of the 28 patients re-operated in our centre, 26 (93%) had autograft valve preservation and they represent the study cohort. At the initial Ross procedure, root remplacement technique was performed in 20 patients and autograft inclusion technique was performed in 6. Mean redo interval was 9.3 + or - 3.5 years and mean age at redo was 44 + or - 13 years. Indications for re-operations were neo-aorta dilatation (n=12; 46%), autograft insufficiency (n=4; 15%) and dilatation with autograft insufficiency (n=10; 40%). Neo-aorta dilatation was repaired using valve-sparing root replacement (n=12, 46%) or ascending aorta replacement (n=10; 40%). Cusp prolapse was repaired by commissural re-suspension (n=1), free margin plication (n=10) or re-suspension with polytetrafluoroethylene (PTFE; n=6). Cusp repair was performed in isolation (n=4) or in association with sparing (n=5) or ascending aorta replacement (n=4).

RESULTS

There was no in-hospital mortality. Two patients having undergone isolated cusp repair needed valve replacement for recurrent insufficiency after 5 days and 8 years postoperatively. At follow-up (100% complete, median: 27 months) all patients were alive, in New York Heart Association (NYHA) class I (n=22; 84%) or II (n=4; 16%). No autograft regurgitation was present in nine patients (five sparing and four ascending aorta replacement); grade I insufficiency was present in 11 (six sparing and five ascending aorta replacement), grade 2 in two (one sparing and one isolated cusp repair) and grade 3 in two (one ascending aorta replacement and one isolated cusp repair). At 3 years, overall freedom from autograft insufficiency > or = grade 3 was 80%.

CONCLUSION

Preservation of the pulmonary autograft valve can be safely performed in selected patients. At midterm, repair of neo-aorta dilatation using valve-sparing root replacement or ascending aorta replacement showed acceptable results. In contrast, results of cusp repair for isolated autograft insufficiency were unsatisfactory.

Для цитирования: de Kerchove Laurent, Boodhwani Munir, Etienne Pierre-Yves, Poncelet Alain, Glineur David, Noirhomme Philippe, Rubay Jean, El Khoury Gebrine. Preservation of the pulmonary autograft after failure of the Ross procedure.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2010. DOI: 10.1016/j.ejcts.2010.02.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.