MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20230103-04

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2023

Impact of Total Corneal Astigmatism Estimated With the Abulafia-Koch Formula Versus Measured With a SS-OCT Biometer on the Refractive Outcomes of a Toric Intraocular Lens in Cataract Surgery.

Rémignon Charles-Henry, Levron Antoine, Agard Emilie, Douma Ikrame, El-Chehab Hussam, Brunet Olivier, Sejournet Lucas, Billant Jeremy, Dot Corinne

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the impact of total corneal astigmatism (TCA) estimated with the Abulafia-Koch formula (TCAABU) versus measured by Total Keratometry (TK), swept-source optical coherence tomography (OCT) coupled with telecentric keratometry (TCATK) on the refractive outcomes after cataract surgery with toric intraocular lens (IOL) implantation.

METHODS

Two hundred one eyes of 146 patients who underwent cataract surgery with toric IOL implantation (XY1AT; HOYA Corporation) were included in this single-center, retrospective study. For each eye, TCAABU (estimated from the anterior keratometry values measured with the IOLMaster 700 [Carl Zeiss Meditec AG]) and TCATK (measured using TK IOLMaster 700) were entered into the HOYA Toric Calculator. Patients were operated on based on TCAABU. For each eye, centroid and mean absolute error in predicted residual astigmatism (EPA) were calculated according to TCA used (TCAABU or TCATK). The cylinder power and the axis of the posterior chamber IOL were compared.

RESULTS

The mean uncorrected distance visual acuity was 0.07 ± 0.12 logMAR, the mean spherical equivalent was 0.11 ± 0.40 D, and mean residual astigmatism was 0.35 ± 0.36 D. Mean centroid EPA was 0.28 D at 132° with TCAABU and 0.35 D at 148° with TCATK (P(x) < .001; P(y) < .01). Mean absolute EPA was 0.46 ± 0.32 D with TCAABU and 0.50 ± 0.37 D with TCATK (P < .01). In the with-the-rule astigmatism subgroup, a deviation from the target of less than 0.50 D was achieved in 68% of eyes with TCAABU versus 50% of eyes with TCATK. The proposed posterior chamber IOL was different depending on the calculation methods used in 86% of cases.

CONCLUSIONS

Both calculation methods showed excellent results. However, the predictability error was significantly reduced when TCAABU was used compared to TCATK measured with the IOLMaster 700 in the whole cohort. Finally, TCA was overestimated by TK in the with-the-rule astigmatism subgroup. [J Refract Surg. 2023;39(3):171-179.].

Для цитирования: Rémignon Charles-Henry, Levron Antoine, Agard Emilie, Douma Ikrame, El-Chehab Hussam, Brunet Olivier, Sejournet Lucas, Billant Jeremy, Dot Corinne. Impact of Total Corneal Astigmatism Estimated With the Abulafia-Koch Formula Versus Measured With a SS-OCT Biometer on the Refractive Outcomes of a Toric Intraocular Lens in Cataract Surgery.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2023. DOI: 10.3928/1081597x-20230103-04.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.