Retrospective Study of a Sustained-Release Intracanalicular Dexamethasone Insert for Treatment of Ocular Inflammation After Cataract and Corneal Surgery.
Аннотация
PURPOSE: To evaluate the effectiveness and safety of a sustained-release intracanalicular dexamethasone insert (Dextenza, Ocular Therapeutix, Inc.) as an adjunctive therapy in patients undergoing cataract and corneal surgery.
PATIENTS AND
METHODS
This retrospective case series contains 18 patients undergoing cataract surgery and 6 patients undergoing corneal surgery. All patients received the Dextenza intracanalicular insert. 6/18 of the patients in the cataract surgery arm were on the standard of care post-surgery topical steroid drop regimen, whereas 11/18 of the patients were on a reduced regimen. 1/18 of the patients was on a drop regimen that deviated from the aforementioned regimens. 2/6 of the patients in the corneal surgery arm were on the standard of care post-surgery topical steroid drop regimen, whereas 3/6 of the patients were on a reduced regimen. 1/6 of the patients were on a drop regimen that deviated from the aforementioned regimens.
RESULTS
The primary outcome measures are intraocular pressure (IOP) levels and anterior chamber inflammation levels across the post-operative recovery period. 1/18 of the patients in the cataract surgery arm and 1/6 of the patients in the corneal surgery arm experienced a clinically significant IOP spike greater than 10 millimeters of mercury (mmHg) above baseline IOP. No patient in either of the study groups had significant inflammation after 1 week post-surgery. 1/18 of the patients in the cataract surgery arm and 1/6 of the patients in the corneal surgery arm experienced a canalicular obstruction.
CONCLUSION
Dextenza with the lower drop protocol showed non-inferiority in terms of inflammation management and safety. As with any steroid delivery mechanism, monitoring IOP is paramount when using Dextenza. One of the patients with a canalicular obstruction had a history of punctal plug implantation, so care should be taken when choosing to implant Dextenza in such a patient.